SWAN-GANZ POLYMER BLEND TRUE SIZE S-TIP CONTROLCATH TD
Edwards Lifesciences LLC
S144F7
In Commercial Distribution
- 00690103017243 ()
- EXTERIOR DIAMETER: 7 F (2.3MM), USABLE LENGTH: 110 CM, RECOMMENDED GUIDEWIRE SIZE: 0.028 IN (0.71 MM), MINIMUM INTRODUCER SIZE: 8 F (2.7 MM)
S144F7
- Pulmonary artery balloon catheter, electrical
SWAN-GANZ TRUE SIZE MONITORING "S" TIP CATHETER
Edwards Lifesciences LLC
S111F7
In Commercial Distribution
- 00690103017236 ()
- EXTERIOR DIAMETER: 7 F (2.3MM), USABLE LENGTH: 110 CM, RECOMMENDED GUIDEWIRE SIZE: 0.038 IN (0.97 MM), MINIMUM INTRODUCER SIZE: 8 F (2.7 MM)
S111F7
- Pulmonary artery balloon catheter, electrical
PRESSURE MONITORING SET
Edwards Lifesciences LLC
PXVMP3X32
In Commercial Distribution
- 00690103016802 ()
- 50690103016807 ()
- Total Volume: 3 Milliliter
PXVMP3X32
- Arterial blood sampling kit
- Invasive-pressure external transducer, single-use
PRESSURE MONITORING SET
Edwards Lifesciences LLC
PXVMP2X22
In Commercial Distribution
- 00690103016765 ()
- 50690103016760 ()
- Total Volume: 3 Milliliter
PXVMP2X22
- Arterial blood sampling kit
- Invasive-pressure external transducer, single-use
PRESSURE MONITORING KIT - STERILE
Edwards Lifesciences LLC
PXVK282
In Commercial Distribution
- 00690103016581 ()
- 50690103016586 ()
- Total Volume: 3 Milliliter
PXVK282
- Arterial blood sampling kit
- Invasive-pressure external transducer, single-use
PRESSURE MONITORING SET
Edwards Lifesciences LLC
PXMK318
In Commercial Distribution
- 00690103014747 ()
- 50690103014742 ()
- Total Volume: 3 Milliliter
PXMK318
- Invasive-pressure external transducer, single-use
PRESSURE MONITORING SET
Edwards Lifesciences LLC
PXCMK315
In Commercial Distribution
- 50690103011543 ()
- 00690103011548 ()
- Total Volume: 3 Milliliter, Length: 56 Inch (142 Centimeter)
PXCMK315
- Invasive-pressure external transducer, single-use
PRESSURE MONITORING SET
Edwards Lifesciences LLC
PXAVMP
In Commercial Distribution
- 00690103011494 ()
- 50690103011499 ()
- TOTAL VOLUME: 3 CC, LENGTH: 68 INCH (172 CENTIMETER)
PXAVMP
- Invasive-pressure external transducer, single-use
- Arterial blood sampling kit
PRESSURE MONITORING SET
Edwards Lifesciences LLC
PX604I
In Commercial Distribution
- 00690103011098 ()
- 50690103011093 ()
PX604I
- Invasive-pressure external transducer, single-use
SWAN-GANZ POLYMER BLEND TRUE SIZE C-TIP CONTROLCATH TD
Edwards Lifesciences LLC
C144F7
In Commercial Distribution
- 00690103005134 ()
- EXTERIOR DIAMETER: 7 F (2.3MM), USABLE LENGTH: 110 CM, RECOMMENDED GUIDEWIRE SIZE: 0.028 IN (0.71 MM), MINIMUM INTRODUCER SIZE: 8 F (2.7 MM)
C144F7
- Pulmonary artery balloon catheter, electrical