Hemapatch Knitted Collagen Coated Vascular Patch
INTERVASCULAR SAS
HEK50/50P (1)
In Commercial Distribution

  • 00384401001577 ()

  • Length: 50 Millimeter
  • Width: 50 Millimeter
HEK50/50P (1)

  • Cardiovascular patch, animal-derived
Hemapatch Knitted Collagen Coated Vascular Patch
INTERVASCULAR SAS
HEK25/50P (1)
In Commercial Distribution

  • 00384401001560 ()

  • Length: 50 Millimeter
  • Width: 25 Millimeter
HEK25/50P (1)

  • Cardiovascular patch, animal-derived
Hemagard Patch Knitted Collagen Coated Vascular Patch
INTERVASCULAR SAS
HGK50/50P (1)
In Commercial Distribution

  • 00384401014843 ()

  • Width: 50 Millimeter
  • Length: 50 Millimeter
HGK50/50P (1)

  • Cardiovascular patch, animal-derived
Hemagard Patch Knitted Collagen Coated Vascular Patch
INTERVASCULAR SAS
HGK25/50P (1)
In Commercial Distribution

  • 00384401014829 ()

  • Width: 25 Millimeter
  • Length: 50 Millimeter
HGK25/50P (1)

  • Cardiovascular patch, animal-derived
Rod, MIS, Lordotic 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
M-01-050
In Commercial Distribution

  • 00814008029631 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 8.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-850-050
In Commercial Distribution

  • 00814008029464 ()

  • Outer Diameter: 8.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 7.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-750-050
In Commercial Distribution

  • 00814008029389 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 6.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-650-050
In Commercial Distribution

  • 00814008029303 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-550-050
In Commercial Distribution

  • 00814008029228 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Dual Lead 4.75X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDR-475-050
In Commercial Distribution

  • 00814008029143 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Cortical Cancellous 8.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCR-850-050
In Commercial Distribution

  • 00814008028962 ()

  • Outer Diameter: 8.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Cortical Cancellous 7.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCR-750-050
In Commercial Distribution

  • 00814008028887 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Cortical Cancellous 6.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCR-650-050
In Commercial Distribution

  • 00814008028801 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Cortical Cancellous 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCR-550-050
In Commercial Distribution

  • 00814008028726 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower Reduction, Cannulated Cortical Cancellous 4.75X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCR-475-050
In Commercial Distribution

  • 00814008028641 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Dual Lead 8.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDM-850-050
In Commercial Distribution

  • 00814008028467 ()

  • Outer Diameter: 8.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Dual Lead 7.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDM-750-050
In Commercial Distribution

  • 00814008028382 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Dual Lead 6.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDM-650-050
In Commercial Distribution

  • 00814008028306 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Dual Lead 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDM-550-050
In Commercial Distribution

  • 00814008028221 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Dual Lead 4.75X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDM-475-050
In Commercial Distribution

  • 00814008028146 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Cortical Cancellous 8.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCM-850-050
In Commercial Distribution

  • 00814008027965 ()

  • Outer Diameter: 8.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Cortical Cancellous 7.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCM-750-050
In Commercial Distribution

  • 00814008027880 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Cortical Cancellous 6.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCM-650-050
In Commercial Distribution

  • 00814008027804 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Cortical Cancellous 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCM-550-050
In Commercial Distribution

  • 00814008027729 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Cortical Cancellous 4.75X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCM-475-050
In Commercial Distribution

  • 00814008027644 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
Rod, Straight 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
S-01-050
In Commercial Distribution

  • 00814008027453 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
Rod, Lordotic 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
L-01-050
In Commercial Distribution

  • 00814008027309 ()

  • Length: 50 Millimeter
  • Outer Diameter: 5.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 8.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-850-050
In Commercial Distribution

  • 00814008027118 ()

  • Outer Diameter: 8.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 8.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-850-050
In Commercial Distribution

  • 00814008026937 ()

  • Outer Diameter: 8.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 7.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-750-050
In Commercial Distribution

  • 00814008026852 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-050
In Commercial Distribution

  • 00814008026777 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-050
In Commercial Distribution

  • 00814008026692 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 6.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-650-050
In Commercial Distribution

  • 00814008026616 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-550-050
In Commercial Distribution

  • 00814008026548 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 5.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-550-050
In Commercial Distribution

  • 00814008026463 ()

  • Outer Diameter: 5.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 4.75X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-475-050
In Commercial Distribution

  • 00814008026371 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 4.75X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-475-050
In Commercial Distribution

  • 00814008026319 ()

  • Outer Diameter: 4.75 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
< 1 >