Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

SET OF 10 ANCHOR BOLTS, LENGTH 25MM, ACCESSORY OF MICRODEEP DEPTH ELECTRODE
DIXI MEDICAL
ANCHOR BOLT
In Commercial Distribution

  • 03664539000671 ()
  • 03664539003290 ()

  • Length: 25 Millimeter
ACS-025SMS-10

  • Depth electrode
microTargeting(TM) Electrode, shielded, tungsten, DZAP(L), sterile
FHC, INC.
MTSWLP(JN)(JN1)-00492
In Commercial Distribution

  • 10873263004927 ()
  • 00873263004920 ()

  • Impedance: Megaohms
  • Length: 251.4 Millimeter
  • Length: 278.4 Millimeter
  • Length: 25 Millimeter
  • Outer Diameter: 0.77 Millimeter
MTSWLP(JN)(JN1)

  • Depth electrode
16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD8
In Commercial Distribution

  • 1199028 ()
  • M364119902FD80 ()

  • Outer Diameter: 16 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
14mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD6
In Commercial Distribution

  • 1199026 ()
  • M364119902FD60 ()

  • Outer Diameter: 14 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
12mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD4
In Commercial Distribution

  • 1199024 ()
  • M364119902FD40 ()

  • Outer Diameter: 12 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
10mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation
MEDICAL DESIGNS LLC
11-9902-FD2
In Commercial Distribution

  • 1199022 ()
  • M364119902FD20 ()

  • Outer Diameter: 10 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
18mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD10
In Commercial Distribution

  • 11990210 ()
  • M364119902FD100 ()

  • Outer Diameter: 18 Millimeter
  • Length: 25 Millimeter


  • Metallic spinal interbody fusion cage
PS, MIS-Tower, Cannulated Cortical Cancellous 7.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-750-030
In Commercial Distribution

  • 00814008026814 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 7.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-750-025
In Commercial Distribution

  • 00814008026807 ()

  • Length: 25 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X60mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-060
In Commercial Distribution

  • 00814008026791 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 60 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X55mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-055
In Commercial Distribution

  • 00814008026784 ()

  • Length: 55 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X45mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-045
In Commercial Distribution

  • 00814008026760 ()

  • Length: 45 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X35mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-035
In Commercial Distribution

  • 00814008026746 ()

  • Length: 35 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-025
In Commercial Distribution

  • 00814008026722 ()

  • Length: 25 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 6.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-650-030
In Commercial Distribution

  • 00814008026579 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 6.5X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-650-025
In Commercial Distribution

  • 00814008026562 ()

  • Length: 25 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 5.5X55mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-550-055
In Commercial Distribution

  • 00814008026555 ()

  • Length: 55 Millimeter
  • Outer Diameter: 5.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Extend, Cannulated Cortical Cancellous 4.75X25mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDCM-475-025
In Commercial Distribution

  • 00814008026197 ()

  • Length: 25 Millimeter
  • Outer Diameter: 4.75 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 7.5X40mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-750-040
In Commercial Distribution

  • 00814008026838 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 40 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 7.5X35mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-750-035
In Commercial Distribution

  • 00814008026821 ()

  • Length: 35 Millimeter
  • Outer Diameter: 7.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-050
In Commercial Distribution

  • 00814008026777 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X40mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-040
In Commercial Distribution

  • 00814008026753 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 40 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Dual Lead 7.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PD-750-030
In Commercial Distribution

  • 00814008026739 ()

  • Outer Diameter: 7.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X60mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-060
In Commercial Distribution

  • 00814008026715 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 60 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X55mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-055
In Commercial Distribution

  • 00814008026708 ()

  • Length: 55 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X50mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-050
In Commercial Distribution

  • 00814008026692 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 50 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X45mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-045
In Commercial Distribution

  • 00814008026685 ()

  • Length: 45 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X40mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-040
In Commercial Distribution

  • 00814008026678 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 40 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X35mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-035
In Commercial Distribution

  • 00814008026661 ()

  • Length: 35 Millimeter
  • Outer Diameter: 6.5 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
PS, MIS-Tower, Cannulated Cortical Cancellous 6.5X30mm. The FOCUS Pedicle Screw System is intended for use in the non-cervical posterior spine (T1-S1) to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, fracture, dislocation, deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis), spinal stenosis, tumor, pseudarthrosis, and failed previous fusion.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
PDC-650-030
In Commercial Distribution

  • 00814008026654 ()

  • Outer Diameter: 6.5 Millimeter
  • Length: 30 Millimeter


  • Bone-screw internal spinal fixation system, non-sterile
< 1 2 3 4 5 >