SEARCH RESULTS FOR: Origin(32 results)
Polypropylene
Innovasis, Inc.
LS-459
In Commercial Distribution
- M711LS4590 ()
LS-459
- Bone graft packing block
The Met One Technologies Kodiak Lumbar Spacer System is a lumbar intervertebral body fusion device that is implanted into the vertebral body space to improve stability of the spine while supporting fusion. The Kodiak Lumbar Spacer System may be implanted bilaterally using a posterior (PLIF) approach, or as a single device employing a transformational (TLIF) approach. The implants have a central endplate window to permit packing of autograft and/or allograft bone, teeth on the superior and inferior surfaces, and lateral windows for radiographic visualization. The implants are additively manufactured from Ti-6Al-4V ELI and are available in a variety of heights, footprints, and lordotic configurations to suit individual patient anatomy.
MET 1 TECHNOLOGIES, LLC
04-07G
In Commercial Distribution
- 00819824028691 ()
04-07G
- Bone graft packing block
COMPACTION BASE
SpineArt SA
TRY-IN 53 00 -N
In Commercial Distribution
- 07640450863478 ()
TRY-IN 53 00 -N
- Bone graft packing block
COMPACTOR
SpineArt SA
TRY-IN 52 00-N
In Commercial Distribution
- 07640450863461 ()
TRY-IN 52 00-N
- Bone graft packing block
COMPACTION BASE
SpineArt SA
JLL-IN 08 01-N
In Commercial Distribution
- 07640178982765 ()
JLL-IN 08 01-N
- Bone graft packing block
COMPACTION BASE
SpineArt SA
SCA-IC 17 00-N
In Commercial Distribution
- 07640332478455 ()
SCA-IC 17 00-N
- Bone graft packing block
icotec Lumbar Cage, Implant Holder for Tamping
icotec AG
38-036
In Commercial Distribution
- 07640164841830 ()
38-036
- Bone graft packing block
Compactor
SpineArt SA
TRY-IN 01 00-N
In Commercial Distribution
- 07640151081881 ()
TRY-IN 01 00-N
- Bone graft packing block
Compaction base
SpineArt SA
DYN-IP 01 03-N
In Commercial Distribution
- 07640139349941 ()
DYN-IP 01 03-N
- Bone graft packing block
Compaction base
SpineArt SA
DYN-IT 00 03-N
In Commercial Distribution
- 07640139342881 ()
DYN-IT 00 03-N
- Bone graft packing block
Compaction base
SpineArt SA
DYN-IP 00 03-N
In Commercial Distribution
- 07640139342423 ()
DYN-IP 00 03-N
- Bone graft packing block
Compactor
SpineArt SA
DYN-IP 00 02-N
In Commercial Distribution
- 07640139342416 ()
DYN-IP 00 02-N
- Bone graft packing block
Base
SpineArt SA
JLL-IN 44 00-N
In Commercial Distribution
- 07640185342989 ()
JLL-IN 44 00-N
- Bone graft packing block
PLIF Graft Packing Block
CURITEVA, INC.
C305-700
In Commercial Distribution
- B648C3057000 ()
- Bone graft packing block
ALIF Graft Packing Block
CURITEVA, INC.
C255-300
In Commercial Distribution
- B648C2553000 ()
- Bone graft packing block
Graft Packer
CURITEVA, INC.
C205-310
In Commercial Distribution
- B648C2053100 ()
- Bone graft packing block
Graft Packing Block
CURITEVA, INC.
C205-300
In Commercial Distribution
- B648C2053000 ()
- Bone graft packing block
TLIF Graft Packing Block
CURITEVA, INC.
C405-700
In Commercial Distribution
- B648C4057000 ()
- Bone graft packing block
EARP, 14X25X08 0° The EARP Interbody System is intended for intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
NVISION BIOMEDICAL TECHNOLOGIES, INC.
EARP1425-0008
Not in Commercial Distribution
- 00810135960007 ()
- Depth: 14 Millimeter
- Width: 25 Millimeter
- Height: 8 Millimeter
- Polymeric spinal interbody fusion cage
18mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD9
In Commercial Distribution
- 1199029 ()
- M364119902FD90 ()
- Outer Diameter: 18 Millimeter
- Length: 21 Millimeter
- Metallic spinal interbody fusion cage
16mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD8
In Commercial Distribution
- 1199028 ()
- M364119902FD80 ()
- Outer Diameter: 16 Millimeter
- Length: 25 Millimeter
- Metallic spinal interbody fusion cage
16mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD7
In Commercial Distribution
- M364119902FD70 ()
- Metallic spinal interbody fusion cage
14mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD6
In Commercial Distribution
- 1199026 ()
- M364119902FD60 ()
- Outer Diameter: 14 Millimeter
- Length: 25 Millimeter
- Metallic spinal interbody fusion cage
14mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD5
In Commercial Distribution
- 1199025 ()
- M364119902FD50 ()
- Outer Diameter: 14 Millimeter
- Length: 21 Millimeter
- Metallic spinal interbody fusion cage
12mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD4
In Commercial Distribution
- 1199024 ()
- M364119902FD40 ()
- Outer Diameter: 12 Millimeter
- Length: 25 Millimeter
- Metallic spinal interbody fusion cage
12mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD3
In Commercial Distribution
- 1199023 ()
- M364119902FD30 ()
- Outer Diameter: 12 Millimeter
- Length: 21 Millimeter
- Metallic spinal interbody fusion cage
10mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation
MEDICAL DESIGNS LLC
11-9902-FD2
In Commercial Distribution
- 1199022 ()
- M364119902FD20 ()
- Outer Diameter: 10 Millimeter
- Length: 25 Millimeter
- Metallic spinal interbody fusion cage
18mm x 25mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD10
In Commercial Distribution
- 11990210 ()
- M364119902FD100 ()
- Outer Diameter: 18 Millimeter
- Length: 25 Millimeter
- Metallic spinal interbody fusion cage
10mm x 21mm Cage; The Asfora Bullet Cage® is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.
MEDICAL DESIGNS LLC
11-9902-FD1
In Commercial Distribution
- M364119902FD10 ()
- 1199021 ()
- Length: 21 Millimeter
- Outer Diameter: 10 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-15-24-00
In Commercial Distribution
- 00813210020023 ()
- Length: 24 Millimeter
- Outer Diameter: 15 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-13-24-00
In Commercial Distribution
- 00813210020016 ()
- Length: 24 Millimeter
- Outer Diameter: 13 Millimeter
- Metallic spinal interbody fusion cage
The Wenzel Spine VariLift Lumbar Interbody Fusion Device is a self-tapping, expandable device with an interior sliding wedge and a posterior end cap. The VariLift-L is a grooved and fluted device with large graft windows positioned each of its four quadrants that provide bony contact with the endplates. VariLift-L is designed to be implanted bi-laterally via posterior (PLIF) approach or as a single device via a transverse (TLIF) approach. VariLift-L may be implanted with or without supplemental fixation and is intended for use with autograft to facilitate fusion. VariLift-L is indicated for intervertebral body fusion of the lumbar spine, from L2 to S1, in skeletally mature patients who have had six months of non-operative treatment. The device is intended for use at either one level or two contiguous levels for the treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
Wenzel Spine, Inc.
CIE2-11-24-00
In Commercial Distribution
- 00813210020009 ()
- Length: 24 Millimeter
- Outer Diameter: 11 Millimeter
- Metallic spinal interbody fusion cage
1