microTargeting single electrode insertion tubes and electrodes kit, 5x, Sterile for use with NexFrame and NexDrive or mT Drive. Each Box Contains: 2x MTDPBN(PA)(DB2) Electrode. 1x IT(DB3) Insertion Tube with Stylet. 1x PT(DB5) Spacer Tube. Individual Specifications: MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm tip expsure, 234.3mm protective tube length, 0.56mm od, 1.0 meg. RZAP IT(DB3) - 194mm length, 1.8mm od, 1.6mm id. PT(DB5) - 194mm length, 1.47mm od, 0.99mm id.
FHC, INC.
FC4000-00115
Not in Commercial Distribution

  • 10873263001155 ()
  • 00873263001158 ()
FC4000

  • Depth electrode
  • Intracerebral cannula, implantable
microTargeting single electrode insertion tubes and electrodes kit, 5x, Sterile for use with NexFrame and NexDrive or mT Drive. Each Box Contains: 2x MTDPBN(PA)(DB2) Electrode. 1x IT(DB3) Insertion Tube with Stylet. 1x PT(DB5) Spacer Tube. Individual Specifications: MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm tip expsure, 234.3mm protective tube length, 0.56mm od, 1.0 meg. RZAP IT(DB3) - 194mm length, 1.8mm od, 1.6mm id. PT(DB5) - 194mm length, 1.47mm od, 0.99mm id.
FHC, INC.
FC4000-00753
In Commercial Distribution

  • 10873263007539 ()
  • 00873263007532 ()
FC4000

  • Intracerebral cannula, nonimplantable, single-use
  • Depth electrode
microTargeting Frame Kit D.ZAP/Lead Insertion, 1x, Sterile, for use with mT Drive or STar Drive. Contains: 34685L: Single D.ZAP Electrode. 66-DA-SD: Drape Sleeve. 66-EL-LP: Patient Lead for LP+. 66-IT-05P: Single Insertion Tube Set.
FHC, INC.
KT-FPK-S20-00508
In Commercial Distribution

  • 00873263005088 ()
KT-FPK-S20

  • Depth electrode
  • Neurological stereotactic surgery system
  • Intracerebral cannula, implantable
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive. Contains: IT(AR16): Insertion Tube. IT(AR17): Insertion Tube w/ Stylet. MTDWLN(AR)(AR2): microTargeting Electrode. 66-CN-ET: Insertion Tube Extractor. Individual Specifications: IT(AR16) - 135mm tube length, 1.981mm OD, 0.96mm ID. IT(AR17) - 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar). MTDWLN(AR)(AR2) - 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
FHC, INC.
KTF1002-00134
Not in Commercial Distribution

  • 10873263001346 ()
  • 00873263001349 ()
KTF1002

  • Intracerebral cannula, implantable
  • Depth electrode
Array Insertion Electrode/Tube with Stylet Kit, 5x, Sterile, for use with Nexframe and microTargeting Drive. Contains: IT(AR8): Insertion Tube w/ Stylet. MTDPBN(PA)(DB2): microTargeting Electrode. Individual Specifications: IT(AR8) - 217mm tube length, 0.89mm OD, 0.58mm ID MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm differential length, 234.2mm protective tube length. 1 Meg RZAP, 0.56mm od
FHC, INC.
FC7100-00132
Not in Commercial Distribution

  • 10873263001322 ()
  • 00873263001325 ()
FC7100

  • Intracerebral cannula, implantable
  • Depth electrode
microTargeting D.ZAP Electrode Kit, 5x, Sterile, Single, 1 Meg, for use with NexFrame and NexDrive or mT Drive. Each box contains: 2x MTDPLN(PA)(DB2) D.ZAP Differential Electrode. 1x IT(DB3) Insertion tube with Stylet. 1x PT(DB5) Protective Tube. Individual Specifications: MTDPLN(PA)(DB2) - 249.2mm electrode length, 10mm tip exposure, 234.2mm protective tube length, .56mm od, 1.0 meg DZAP(L) IT(DB3) - 194mm length, 1.8mm od, 1.6mm id, PT(DB5) - 194mm length, 1.47mm od, 0.99mm id
FHC, INC.
FC4001-00116
Not in Commercial Distribution

  • 10873263001162 ()
  • 00873263001165 ()
FC4001

  • Depth electrode
  • Intracerebral cannula, implantable
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive. Contains: IT(AR16): Insertion Tube. IT(AR17): Insertion Tube w/ Stylet. MTDWLN(AR)(AR2): microTargeting Electrode. 66-CN-ET: Insertion Tube Extractor. Individual Specifications: IT(AR16) - 135mm tube length, 1.981mm OD, 0.96mm ID. IT(AR17) - 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar). MTDWLN(AR)(AR2) - 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
FHC, INC.
KTF1002-00758
In Commercial Distribution

  • 10873263007584 ()
  • 00873263007587 ()
KTF1002

  • Intracerebral cannula, nonimplantable, single-use
  • Depth electrode
Array Insertion Electrode/Tube with Stylet Kit, 5x, Sterile, for use with Nexframe and microTargeting Drive. Contains: IT(AR8): Insertion Tube w/ Stylet. MTDPBN(PA)(DB2): microTargeting Electrode. Individual Specifications: IT(AR8) - 217mm tube length, 0.89mm OD, 0.58mm ID MTDPBN(PA)(DB2) - 249.2mm electrode length, 10mm differential length, 234.2mm protective tube length. 1 Meg RZAP, 0.56mm od
FHC, INC.
FC7100-00756
In Commercial Distribution

  • 10873263007560 ()
  • 00873263007563 ()
FC7100

  • Depth electrode
  • Intracerebral cannula, nonimplantable, single-use
microTargeting D.ZAP Electrode Kit, 5x, Sterile, Single, 1 Meg, for use with NexFrame and NexDrive or mT Drive. Each box contains: 2x MTDPLN(PA)(DB2) D.ZAP Differential Electrode. 1x IT(DB3) Insertion tube with Stylet. 1x PT(DB5) Protective Tube. Individual Specifications: MTDPLN(PA)(DB2) - 249.2mm electrode length, 10mm tip exposure, 234.2mm protective tube length, .56mm od, 1.0 meg DZAP(L) IT(DB3) - 194mm length, 1.8mm od, 1.6mm id, PT(DB5) - 194mm length, 1.47mm od, 0.99mm id
FHC, INC.
FC4001-00754
In Commercial Distribution

  • 10873263007546 ()
  • 00873263007549 ()
FC4001

  • Depth electrode
  • Intracerebral cannula, nonimplantable, single-use
microTargeting Platform Procedure Consumables Kit, 1x, sterile, for use with mT or STar Drive, mT Platform and Guideline 4000 LP+. Contains: 44975L: D.ZAP Tungsten Differential Electrode - - 220.72mm electrode length, 10mm differential, 205.72mm protective tube length, DZAP(L) 1Meg, 0.55mm od. 66-DA-SD: Sterile Drape Sleeve for motor 66-EL-LP: Patient Lead for Guideline 4000 LP+ 66-IT-03P: Sterile Single Insertion Tube Set - IT(MP1) - 184.1mm tube length, 1.83mm od, 1.6mm id with Stylet PT(MP1) - Diameter reduction tube 0.58mm id
FHC, INC.
KT-PPK-S-00366
In Commercial Distribution

  • 00873263003664 ()
KT-PPK-S

  • Depth electrode
  • Patient surgical drape, single-use
  • Intracerebral cannula, implantable
< 1 2 >