Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

DEPTHALON ELECTRODE, PLATINUM, 16 MACRO CONTACTS, 48 MICROWIRE CONTACTS, MINI CONNECTOR, 1 EXIT, 4 LEADS, 4 EXITS
PMT CORPORATION
2104-16-48-003
In Commercial Distribution

  • 00650551146629 ()


  • Depth electrode
Depthalon Electrode, Platinum, 7 Macro Contacts, 16 Microwire contacts, 52mm recording length, Mini connector, 1 exit, 4 leads, 4 exits
PMT CORPORATION
2104-07-057-003
In Commercial Distribution

  • 00650551144571 ()


  • Depth electrode
Depthalon Electrode, Platinum, 7 Macro Contacts, 57 Microwire contacts, 44mm recording length, Mini connector, 1 exit, 4 leads, 4 exits
PMT CORPORATION
2104-07-057-002
In Commercial Distribution

  • 00650551144564 ()


  • Depth electrode
Depthalon Electrode, Platinum, 8 Macro Contacts, 16 Microwire contacts, 38.5mm recording length, Miniconnector, 1 exit, 2 leads, 2 exits
PMT CORPORATION
2104-08-16-004
In Commercial Distribution

  • 00650551144465 ()


  • Depth electrode
Depthalon Electrode, Platinum, 8 Macro Contacts, 16 Microwire contacts, 38.5mm recording length, Inline connector, 1 exit, 2 leads, 2 exits
PMT CORPORATION
2104-08-16-003
In Commercial Distribution

  • 00650551144397 ()


  • Depth electrode
Depthalon sEEG Electrode, Platinum, 4 contacts, 17mm recording length, Mini connector, 1 Exit, 1 Lead, 1 Tail
PMT CORPORATION
2102-04-145
In Commercial Distribution

  • 00650551144380 ()


  • Depth electrode
MICROWIRE DEPTHALON ELECTRODE, 57 MICROWIRE CONTACTS, MINI CONNECTOR
PMT CORPORATION
2104-07-57-001
In Commercial Distribution

  • 00650551143871 ()

  • Microwire Diameter 40 Micrometer
  • Main Tube Length 20 Centimeter
  • Contact Size 1.5 Millimeter
2104-07-57-001

  • Depth electrode
sEEG, PLATINUM, 14 CONTACT, MINI CONNECTOR, REMOVEABLE STYLET, FOR 2.4MM DRILL
PMT CORPORATION
2102-14-146
In Commercial Distribution

  • 00650551143741 ()

  • Main Tube Length 27 Centimeter
  • Spacing 7 Millimeter
  • Recording Depth 93 Millimeter
  • Contact Length 2 Millimeter
  • Outer Diameter: 0.8 Millimeter
2102-14-146

  • Depth electrode
MICROWIRE DEPTHALON ELECTRODE, 48 MICROWIRE CONTACTS, MINI CONNECTOR
PMT CORPORATION
2104-07-48-001
In Commercial Distribution

  • 00650551143710 ()

  • Microwire Diameter 25 Micrometer
  • Main Tube Length 20 Centimeter
  • Contact Size 5 Millimeter
2104-07-48-001

  • Depth electrode
sEEG, PLATINUM, 16 CONTACT, MINI CONNECTOR, REMOVEABLE STYLET, FOR 2.4MM DRILL
PMT CORPORATION
2102-16-291
In Commercial Distribution

  • 00650551143451 ()

  • Main Tube Length 27 Centimeter
  • Spacing 3.5 Millimeter
  • Recording Depth 54.5 Millimeter
  • Contact Length 2 Millimeter
  • Outer Diameter: 0.8 Millimeter
2102-16-291

  • Depth electrode
sEEG, PLATINUM, 16 CONTACT, MINI CONNECTOR, REMOVEABLE STYLET, FOR 2.4MM DRILL
PMT CORPORATION
2102-16-118
In Commercial Distribution

  • 00650551143444 ()

  • Main Tube Length 27 Centimeter
  • Spacing 4.43 Millimeter
  • Recording Depth 67.8 Millimeter
  • Contact Length 1.3 Millimeter
  • Outer Diameter: 0.8 Millimeter
2102-16-118

  • Depth electrode
sEEG, PLATINUM, 16 CONTACT, MINI CONNECTOR, REMOVEABLE STYLET, FOR 2.4MM DRILL
PMT CORPORATION
2102-16-117
In Commercial Distribution

  • 00650551143437 ()

  • Main Tube Length 27 Centimeter
  • Spacing 3.97 Millimeter
  • Recording Depth 60.8 Millimeter
  • Contact Length 1.3 Millimeter
  • Outer Diameter: 0.8 Millimeter
2102-16-117

  • Depth electrode
sEEG, PLATINUM, 16 CONTACT, MINI CONNECTOR, REMOVEABLE STYLET, FOR 2.4MM DRILL
PMT CORPORATION
2102-16-116
In Commercial Distribution

  • 00650551143420 ()

  • Main Tube Length 27 Centimeter
  • Spacing 3.5 Millimeter
  • Recording Depth 53.8 Millimeter
  • Contact Length 1.3 Millimeter
  • Outer Diameter: 0.8 Millimeter
2102-16-116

  • Depth electrode
sEEG, PLATINUM, 14 CONTACT, MINI CONNECTOR, REMOVEABLE STYLET, FOR 2.4MM DRILL
PMT CORPORATION
2102-14-116
In Commercial Distribution

  • 00650551143413 ()

  • Main Tube Length 27 Centimeter
  • Spacing 3.5 Millimeter
  • Recording Depth 46.8 Millimeter
  • Contact Length 1.3 Millimeter
  • Outer Diameter: 0.8 Millimeter
2102-14-116

  • Depth electrode
sEEG, PLATINUM, 12 CONTACT, MINI CONNECTOR, REMOVEABLE STYLET, FOR 2.4MM DRILL
PMT CORPORATION
2102-12-116
In Commercial Distribution

  • 00650551143406 ()

  • Main Tube Length 27 Centimeter
  • Spacing 3.5 Millimeter
  • Recording Depth 39.8 Millimeter
  • Contact Length 1.3 Millimeter
  • Outer Diameter: 0.8 Millimeter
2102-12-116

  • Depth electrode
sEEG, PLATINUM, 10 CONTACT, MINI CONNECTOR, REMOVEABLE STYLET, FOR 2.4MM DRILL
PMT CORPORATION
2102-10-116
In Commercial Distribution

  • 00650551143390 ()

  • Main Tube Length 27 Centimeter
  • Spacing 3.5 Millimeter
  • Recording Depth 32.8 Millimeter
  • Contact Length 1.3 Millimeter
  • Outer Diameter: 0.8 Millimeter
2102-10-116

  • Depth electrode
PUMP 8637-20 SYNCHMED II 20ML PF
MEDTRONIC, INC.
8637-20
In Commercial Distribution

  • 00643169100831 ()

  • Total Volume: 20.0 Milliliter


  • Implantable intrathecal infusion pump, programmable
PUMP 8637-40 SYNCHMED II 40ML PF
MEDTRONIC, INC.
8637-40
In Commercial Distribution

  • 00643169100824 ()

  • Total Volume: 40.0 Milliliter


  • Implantable intrathecal infusion pump, programmable
PLATINUM, 16 CONTACT, MINI CONNECTOR, REMOVABLE STYLET, FOR 2.4MM DRILL, 0.8MM OD, 2MM CONTACT LENGTH, 61.55MM RECORDING DEPTH, 3.97MM SPACING, 60CM MAIN TUBE LENGTH
PMT CORPORATION
2102-16-136
In Commercial Distribution

  • 00650551150626 ()


  • Depth electrode
PLATINUM, 6 CONTACT, MINI CONNECTOR, REMOVABLE STYLET, FOR 2.4MM DRILL, 0.8MM OD, 2MM CONTACT LENGTH, 19.5MM RECORDING DEPTH, 3.5MM SPACING, 60CM MAIN TUBE LENGTH
PMT CORPORATION
2102-06-131
In Commercial Distribution

  • 00650551150619 ()


  • Depth electrode
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
EDSEP
Not in Commercial Distribution

  • M272EDSEP1 ()
  • 10381780037088 ()


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D5L25
In Commercial Distribution

  • M272AU8D5L251 ()
  • 10381780036531 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L5
In Commercial Distribution

  • M272AU8D10L51 ()
  • 10381780036524 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU8D10L25
In Commercial Distribution

  • M272AU8D10L251 ()
  • 10381780036517 ()

  • 8 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L5
In Commercial Distribution

  • M272AU6D10L51 ()
  • 10381780036449 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU6D10L25
In Commercial Distribution

  • M272AU6D10L251 ()
  • 10381780036432 ()

  • 6 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D5L25
In Commercial Distribution

  • M272AU4D5L251 ()
  • 10381780036326 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L5
In Commercial Distribution

  • M272AU4D10L51 ()
  • 10381780036319 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L25
In Commercial Distribution

  • M272AU4D10L251 ()
  • 10381780036302 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU12D5L25
In Commercial Distribution

  • M272AU12D5L251 ()
  • 10381780036111 ()

  • 12 platinum contacts


  • Depth electrode
< 1 ... 46 47 48 49 50 ... 82 >