Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU12D5L25
Not in Commercial Distribution

  • M272AU12D5L251 ()
  • 10381780036111 ()

  • 12 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU4D10L5
Not in Commercial Distribution

  • M272AU4D10L51 ()
  • 10381780036319 ()

  • 4 platinum contacts


  • Depth electrode
The Auragen™ depth electrodes are designed for intraoperative monitoring of cortical electrical activity in order to define the location of epileptogenic foci. They are inserted stereotaxically into the brain. Depth electrodes are available with 4 to 12 platinum/iridium contacts. The type of depth electrode used is dependent on the procedure and the size of area being tested.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
AU10D5L25
Not in Commercial Distribution

  • M272AU10D5L251 ()
  • 10381780036104 ()

  • 10 platinum contacts


  • Depth electrode
Balance harness for balance training activities
M.A.S.S. Rehab, LLC
Standard
In Commercial Distribution

  • G505MRBHS0 ()


  • Gait rehabilitation system harness
Polypropylene
Innovasis, Inc.
LS-459
In Commercial Distribution

  • M711LS4590 ()
LS-459

  • Bone graft packing block
Each Vascular Solutions D-Stat® flowable hemostat (D-Stat) includes the following components: Thrombin vial (5,000 units); Collagen (200mg), contained in 10ml syringe with attached mixing luer; Diluent vial (5ml); Mixing accessories (10ml syringe and needleless, non-coring vial access device); Applicator tips: (1) small bore tip, (1) 20-Gauge, 2.75" needle. The thrombin is a protein substance produced through a conversion reaction in which prothrombin of bovine origin is activated by tissue thromboplastin of bovine-origin in the presence of calcium chloride. It is supplied as a sterile powder that has been freeze-dried in the final container. Also contained in the thrombin vial are mannitol and sodium chloride. Mannitol is included to make the dried product friable and more readily soluble. The material contains no preservative and has been chromatographically purified. Thrombin requires no intermediate physiological agent for its reaction. It converts fibrinogen directly to fibrin. The collagen is a soft, white, pliable, absorbent hemostatic agent derived from purified bovine deep flexor tendon. It is prepared in a loose fibrous form. Collagen attracts platelets that adhere to the fibrils and undergo the release phenomenon to trigger aggregation of platelets into thrombi in the interstices of the fibrous mass. The collagen provides a three-dimensional matrix for additional strengthening of the clot. The effect on platelet adhesion and aggregation is not inhibited by heparin in vitro. The diluent is a sterile solution of calcium chloride and water, buffered with tromethamine (TRIS). Using the mixing accessories, both the thrombin and collagen are reconstituted with the diluent prior to use. The hemostat is delivered to the intended treatment site using the provided applicator tips. Hemostasis is achieved by the physiological coagulation-inducing properties of the D-Stat. The D-Stat is biocompatible, non-pyrogenic, and intended to be left in situ.
Vascular Solutions, Inc.
4000
In Commercial Distribution

  • M20640000 ()
  • M20640001 ()


  • Collagen haemostatic agent, non-antimicrobial
The Ekso is a powered motorized orthosis. It consists of a fitted metal brace that supports the legs, feet, and torso. It is worn via straps on the body, legs, and feet. Battery powered motors drive knee and hip joints. It has an integrated solid torso containing the computer and power supply. It has a hand-held user interface to specify settings and initiate steps. The Ekso is used with a cane, crutch, or walker.
EKSO BIONICS, INC.
GT
In Commercial Distribution

  • B1431200000 ()


  • Programmable ambulation exoskeleton, clinical
EKSO BIONICS SYSTEM, Ekso GT
EKSO BIONICS, INC.
EKSOGT
In Commercial Distribution

  • B168EKSOGT0 ()
EKSOGT

  • Programmable ambulation exoskeleton, clinical
EKSO BIONICS SYSTEM, Ekso NR
EKSO BIONICS, INC.
EKSONR
In Commercial Distribution

  • B168EKSONR0 ()
EKSONR

  • Programmable ambulation exoskeleton, clinical
Smoke Filtration System (230 Volts AC)
UTAH MEDICAL PRODUCTS, INC.
230VAC
In Commercial Distribution

  • H671SSE2000 ()
SSE-200

  • Surgical plume evacuation system
Smoke Filtration System (115 Volts AC)
UTAH MEDICAL PRODUCTS, INC.
115VAC
In Commercial Distribution

  • H671SSE1000 ()
SSE-100

  • Surgical plume evacuation system
GammaPro Angled Standard Probe used for wireless ionizing radiation detection.
Kubtec
K0021C01
In Commercial Distribution

  • B619GPROSTDANGPROBE0 ()


  • Mobile gamma camera system
Table with installed software is used with wireless battery powered probes (different shapes and sizes) to detect a determined range of gamma radiation energies and maximizes sensitivity and directivity.
Kubtec
K0017C01
In Commercial Distribution

  • B619GPROCASETABL2 ()


  • Mobile gamma camera system
GammaPro Hi-Sense Probe with Tablet and Carry Case used for wireless ionizing radiation detection.
Kubtec
K0019C02
In Commercial Distribution

  • B619GPROHISKIT0 ()


  • Mobile gamma camera system
GammaPro High Sensitivity Probe used for wireless ionizing radiation detection.
Kubtec
K0019C01
In Commercial Distribution

  • B619GPROHISPROBE0 ()


  • Mobile gamma camera system
GammaPro Laparoscopic Probe used for wireless ionizing radiation detection.
Kubtec
K0020C01
In Commercial Distribution

  • B619GPROLAPPROBE0 ()


  • Mobile gamma camera system
GammaPro Laparoscopic Probe with Tablet and Carry Case used for wireless ionizing radiation detection.
Kubtec
K0020C02
In Commercial Distribution

  • B619GPROLAPKIT0 ()


  • Mobile gamma camera system
GammaPro Kit with Standard probe, Tablet and Carry Case used for wireless ionizing radiation detection.
Kubtec
K0018C02
In Commercial Distribution

  • B619GPROSTDKIT0 ()


  • Mobile gamma camera system
GammaPro Straight Standard Probe for wireless ionizing radiation detection.
Kubtec
K0018C01
In Commercial Distribution

  • B619GPROSTDPROBE0 ()


  • Mobile gamma camera system
Harness for Healing Solutions Robotic Trainer
M.A.S.S. Rehab, LLC
Standard
In Commercial Distribution

  • G505MRHSH0 ()


  • Gait rehabilitation system harness
Indego is a computerized, powered exoskeleton, designed to restore walking function for impaired individuals.
EKSO BIONICS, INC.
501-100-000
In Commercial Distribution

  • M704501100000 ()


  • Programmable ambulation exoskeleton, clinical
Indego Therapy is a computerized, adjustable-fit powered exoskeleton, designed to restore walking function for impaired individuals.
EKSO BIONICS, INC.
501-110-001
In Commercial Distribution

  • M704501110001 ()


  • Programmable ambulation exoskeleton, clinical
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516227090 ()
22709

  • Electronystagmograph
  • Dynamic visual acuity testing system
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516222210 ()
22221

  • Electronystagmograph
  • Dynamic visual acuity testing system
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin.
Instrumentation Difra SA
NysStar II
In Commercial Distribution

  • B516221340 ()
22134

  • Electronystagmograph
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR I is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests). NYSSTAR I is able to record all eye movements, as well horizontal, as vertical and even rotary movements on option. The calibration carried out by NYSSTAR I is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin.
Instrumentation Difra SA
NysStar I
In Commercial Distribution

  • B516221280 ()
22128

  • Electronystagmograph
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. HEADSTAR is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus), the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests and the Video Head Impulse Test. HEADSTAR is a nystagmography system and is able to record movements of one eye: horizontal, vertical and rotary on option. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. HEADSTAR is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run VHIT tests and other oculomotor tests.
Instrumentation Difra SA
HeadStar V2.0
In Commercial Distribution

  • B516320980 ()
32098

  • Electronystagmograph
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. NYSSTAR II is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus) and the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests. NYSSTAR II is a nystagmography system and is able to record simultaneously both eyes movements, as well horizontal, as vertical. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. NYSSTAR IU is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run specific oculomotor tests.
Instrumentation Difra SA
NysStar II with VOR
In Commercial Distribution

  • B516311790 ()
31179

  • Electronystagmograph
  • Dynamic visual acuity testing system
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
40M08
Not in Commercial Distribution

  • M27240M081 ()
  • 10381780034766 ()

  • Insertion needle 64mm Length


  • Depth electrode
The Integra Sphenoidal Electrode is designed for investigative intraoperative monitoring of cortical electrical activity specifically at the undersurface of the temporal lobe. It has one platinum contact and is supplied with an insertion needle.
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
EDSEP
Not in Commercial Distribution

  • M272EDSEP1 ()
  • 10381780037088 ()


  • Depth electrode
The videonystagmography performed by a camera and infra red light measures and records the eye movement, which is analyzed by the software. HEADSTAR is the essential tool to study the various functions of balance, namely the oculomotricity (ocular saccades, pursuit, optokinetic nystagmus), the study of the vestibular system (spontaneous and positional nystagmi, rotary tests, caloric tests and the Video Head Impulse Test. HEADSTAR is a nystagmography system and is able to record movements of one eye: horizontal, vertical and rotary on option. The calibration carried out by camera is stable and should only be made once at the beginning of the examination. The recording by camera removes all artefacts due to the changes of polarity between the electrodes and the skin like with the interferences of electric and electrophysiological origin. HEADSTAR is also equipped with gyroscope to record movements of the patient's head. Combination of movements of the eye and of the head allow to run VHIT tests and other oculomotor tests.
Instrumentation Difra SA
HeadStar
In Commercial Distribution

  • B516221350 ()
22135

  • Electronystagmograph
Simple two-loop spotting harness for gait and balance training.
M.A.S.S. Rehab, LLC
Standard
In Commercial Distribution

  • G505MRMS0 ()


  • Gait rehabilitation system harness
GRAFT PACKING BLOCK
Synthes GmbH
03.841.055
In Commercial Distribution

  • 07611819473140 ()
  • H981038410550 ()
  • 10705034732350 ()
03841055

  • Bone graft packing block
PACKING BLOCK FOR ZERO-P IMPLANTS
Synthes GmbH
03.617.984
In Commercial Distribution

  • 07611819969780 ()
  • H981036179840 ()
  • 10705034717388 ()
03617984

  • Bone graft packing block
ACF GRAFT PACKING BLOCK
Synthes GmbH
396.996
In Commercial Distribution

  • H9813969960 ()
  • 10705034778204 ()
396996

  • Bone graft packing block
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 30mm
In Commercial Distribution

  • D960LVX00301 ()
30101109

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 28mm
In Commercial Distribution

  • D960LVX00281 ()
30101108

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 25mm
In Commercial Distribution

  • D960LVX00251 ()
30101107

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 24mm
In Commercial Distribution

  • D960LVX00241 ()
30101110

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 22mm
In Commercial Distribution

  • D960LVX00221 ()
30101106

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 20mm
In Commercial Distribution

  • D960LVX00201 ()
30101105

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 18mm
In Commercial Distribution

  • D960LVX00181 ()
30101104

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 16mm
In Commercial Distribution

  • D960LVX00161 ()
30101103

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 14mm
In Commercial Distribution

  • D960LVX00141 ()
30101102

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 12mm
In Commercial Distribution

  • D960LVX00121 ()
30101101

  • Dental appliance fabrication material, ceramic
Origin Live are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Live can be used for all dental constructions incl. bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
Live 10mm
In Commercial Distribution

  • D960LVX00101 ()
30101100

  • Dental appliance fabrication material, ceramic
Origin Beyond Plus Pre-shaded multi are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Beyond Plus Pre-shaded multi can be used for all dental constructions include bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
98D14mm OM2
In Commercial Distribution

  • D960BPMM2141 ()
30112199

  • Dental appliance fabrication material, ceramic
Origin Beyond Plus Pre-shaded multi are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Beyond Plus Pre-shaded multi can be used for all dental constructions include bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
98D14mm C2
In Commercial Distribution

  • D960BPMC2141 ()
30112210

  • Dental appliance fabrication material, ceramic
Origin Beyond Plus Pre-shaded multi are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Beyond Plus Pre-shaded multi can be used for all dental constructions include bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
98D14mm C1
In Commercial Distribution

  • D960BPMC1141 ()
30112209

  • Dental appliance fabrication material, ceramic
Origin Beyond Plus Pre-shaded multi are dental mill blanks made from zirconium dioxide for the manufacture of dental prostheses. Origin Beyond Plus Pre-shaded multi can be used for all dental constructions include bridges over 4 units with up to two connected pontics in the front and side tooth area.
B & D DENTAL CORP.
98D14mm B4
In Commercial Distribution

  • D960BPMB4141 ()
30112208

  • Dental appliance fabrication material, ceramic
< 1 2 3 4 >