SEARCH RESULTS FOR: 跨境出海推广费用价格多少🚩TG@yuantou2048🚩最快24小时见效出海推广营销一条龙(6882 results)
FHC Universal Style Stretcher Pad 24 X 76 X 4 Poly Foam With Two Angled Corners And Two Rounded Corners With Dura-Comfort Material With 2 Wide Loop Velcro Sewn To Bottom Of The Pads And Mating Adhesive Hook Velcro Supplied Just Peel The Adhesive And Place The Pad Onto Stretcher.
FUTURE HEALTH CONCEPTS, INC.
BB24X76X4
In Commercial Distribution
- B337BB24X76X41 ()
BB24X76X4
- Stretcher mattress
Overall size 24”W x 20.5”D x 64.75”T.
7.45 Cubic ft. storage
Upper Chamber I.D. 20”W x 17”D x 13.5”T
2.65 Cubic ft. storage
Temperature Range: 90-160 F
Accuracy +/- 1 degrees F of set point
Lower Chamber I.D. 20”W x 17”D x 24.5”T
4.8 Cubic ft. storage
Temperature Range: 90-160 F
Accuracy +/- 2 degrees F of set point
Pass thru
3 Adjustable shelves
Digital control
Stainless steel doors
Audible and visual over-temp alarm
Data logger
Foot levelers
Electrical:
120V, 7.5 Amp, 50/60 Hz
.49 kw/hr, 1678 btu/hr
M.A.C. MEDICAL INC.
FHCDWC2460-18-TL-D-P
In Commercial Distribution
- B286FHCDWC246018TLDP1 ()
FHCDWC2460-18-TL-D-P
- Blanket warming cabinet, dry-heat
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
NOVOSCI CORP.
SHC02
In Commercial Distribution
- B066SHC023 ()
- B066SHC020 ()
SHC02
- Cardiopulmonary bypass system blood tubing set
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
NOVOSCI CORP.
SFC02
In Commercial Distribution
- B066SFC023 ()
- B066SFC020 ()
SFC02
- Cardiopulmonary bypass system blood tubing set
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
NOVOSCI CORP.
SFB02
In Commercial Distribution
- B066SFB023 ()
- B066SFB020 ()
SFB02
- Cardiopulmonary bypass system blood tubing set
A collection of sterile devices including tubing and typically clamps, filters, connectors, and stopcocks, used in a circuit for a cardiopulmonary bypass procedure. The tubing is typically polymeric and may be heparin coated. It is typically used in the blood pump head of a cardiopulmonary bypass system. The tubing, when used in a roller type pump, will be cyclically compressed by the blood pump to cause the blood to flow through the heart-lung bypass system. This is a single-use device.
NOVOSCI CORP.
SDB02
In Commercial Distribution
- B066SDB023 ()
- B066SDB020 ()
SDB02
- Cardiopulmonary bypass system blood tubing set
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
NOVOSCI CORP.
301028-000
In Commercial Distribution
- B0663010280006 ()
- B0663010280000 ()
- B0663010280005 ()
- B0663010280004 ()
- B0663010280003 ()
301028-000
- Cardioplegia solution administration adaptor
A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
NOVOSCI CORP.
301022-000
In Commercial Distribution
- B0663010220006 ()
- B0663010220000 ()
- B0663010220005 ()
- B0663010220004 ()
- B0663010220003 ()
301022-000
- Cardioplegia solution administration adaptor
No Description
BIOPRO, INC.
20967
In Commercial Distribution
- M209209670 ()
- Orthopaedic reamer guide
The CQ-36 / D-04B TDP therapy lamp has two independent emission heads, each containing a mineral plate consisting of 33 elements essential to the human body. When this mineral plate is activated by a built-in heating element begins to emit FIR (far infrared) waves along with the ionized minerals which easily penetrates deep into the body to be absorbed.
The CQ-36 lamp is a free standing floor lamp with a 24" diameter wheeled base for convenient transport. With the articulating arms, each emission head can be positioned as low as 12" to as high as 52" from the floor. Tilt and swivel head allow multiple angles of treatment. Quick and easy assembly.
A & A MEDICAL SUPPLIES INC.
CQ-36
In Commercial Distribution
- B465CQ360 ()
- Weight: 25 Pound
- Width: 24 Inch
- Adjustable Min/Max Height: 33.5"/62" above floor
D-04B
- Musculoskeletal infrared phototherapy unit, non-wearable