SEARCH RESULTS FOR: (*cryptocurrency exchange hong kong馃挷itenthusiasts.com馃挷Enthusiasts*)(29683 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
CROSPERIO RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B35040MR
In Commercial Distribution
- 04540778162471 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.5 Fr
- Distal Shaft Diameter; 3.5 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 3.5 mm
BD-B35040MR
- Peripheral angioplasty balloon catheter, basic
CROSPERIO RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B30040MR
In Commercial Distribution
- 04540778162457 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.5 Fr
- Distal Shaft Diameter; 3.5 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 3.0 mm
BD-B30040MR
- Peripheral angioplasty balloon catheter, basic
CROSPERIO RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B25040MR
In Commercial Distribution
- 04540778162433 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.5 Fr
- Distal Shaft Diameter; 3.5 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 2.5 mm
BD-B25040MR
- Peripheral angioplasty balloon catheter, basic
CROSPERIO RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B20040MR
In Commercial Distribution
- 04540778162419 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.5 Fr
- Distal Shaft Diameter; 3.5 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 2.0 mm
BD-B20040MR
- Peripheral angioplasty balloon catheter, basic
CROSPERIO RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B15040MR
In Commercial Distribution
- 04540778162396 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.5 Fr
- Distal Shaft Diameter; 3.5 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 1.5 mm
BD-B15040MR
- Peripheral angioplasty balloon catheter, basic
CROSPERIO RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B15020MR
In Commercial Distribution
- 04540778162372 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.5 Fr
- Distal Shaft Diameter; 3.5 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 20 mm
- Balloon Diameter; 1.5 mm
BD-B15020MR
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46 mm).
KANEKA CORPORATION
BD-F60200LW
In Commercial Distribution
- 04540778162358 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 4.3 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 200 mm
- Balloon Diameter; 6.0 mm
BD-F60200LW
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46 mm).
KANEKA CORPORATION
BD-F50200LW
In Commercial Distribution
- 04540778162334 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 4.3 Fr
- Catheter Working Length; 1500 mm
- Balloon Length; 200 mm
- Balloon Diameter; 5.0 mm
BD-F50200LW
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46 mm).
KANEKA CORPORATION
BD-F40200LW
In Commercial Distribution
- 04540778162310 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.9 Fr
- Catheter Working Length; 1500 mm
- Balloon Length; 200 mm
- Balloon Diameter; 4.0 mm
BD-F40200LW
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46 mm).
KANEKA CORPORATION
BD-F30200LW
In Commercial Distribution
- 04540778162297 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Shaft Diameter; 3.9 Fr
- Catheter Working Length; 1500 mm
- Balloon Length; 200 mm
- Balloon Diameter; 3.0 mm
BD-F30200LW
- Peripheral angioplasty balloon catheter, basic