Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

microTargeting(TM) Electrode, differential, sterile, platinum/iridium, glass insulated
FHC, INC.
MTDPBP(AO)(AO1)-00322
In Commercial Distribution

  • 10873263003227 ()
  • 00873263003220 ()

  • Impedance: Megaohms
  • Outer Diameter: 1.24 Millimeter
  • Length: 274 Millimeter
  • Length: 3 Millimeter
  • Length: 282 Millimeter
MTDPBP(AO)(AO1)

  • Depth electrode
microTargeting(TM) Electrode, backloaded, tungsten, sterile
FHC, INC.
MTBWAP(JJ2)-00309
In Commercial Distribution

  • 10873263003098 ()
  • 00873263003091 ()

  • Length: 15 Millimeter
  • Outer Diameter: 0.34 Millimeter
  • Length: 285 Millimeter
  • Impedance: Megaohms
MTBWAP(JJ2)

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(Z), for Nexframe(R) and STar(R) Drive
FHC, INC.
5705Z-00289
In Commercial Distribution

  • 10873263002893 ()
  • 00873263002896 ()

  • Outer Diameter: 0.56 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 227.2 Millimeter
  • Length: 242.2 Millimeter
5705Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(L), for use with Nexframe(R) and STar Drive
FHC, INC.
5705L-00283
In Commercial Distribution

  • 10873263002831 ()
  • 00873263002834 ()

  • Length: 227.2 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Length: 242.2 Millimeter
  • Impedance: Megaohms
5705L

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(Z), for use with Nexframe(R)
FHC, INC.
5005Z-00277
In Commercial Distribution

  • 10873263002770 ()
  • 00873263002773 ()

  • Impedance: Megaohms
  • Length: 234.2 Millimeter
  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
  • Outer Diameter: 0.56 Millimeter
5005Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(L), for use with Nexframe(R)
FHC, INC.
5005L-00273
In Commercial Distribution

  • 10873263002732 ()
  • 00873263002735 ()

  • Length: 249.2 Millimeter
  • Length: 10 Millimeter
  • Length: 234.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
5005L

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.Zap(Z), for use with Platform
FHC, INC.
44975Z-00267
In Commercial Distribution

  • 10873263002671 ()
  • 00873263002674 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 205.72 Millimeter
  • Length: 10 Millimeter
  • Length: 220.72 Millimeter
44975Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, D.ZAP(L), for use with Platform
FHC, INC.
44975L-00263
In Commercial Distribution

  • 10873263002633 ()
  • 00873263002636 ()

  • Impedance: Megaohms
  • Length: 220.72 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
  • Length: 205.72 Millimeter
44975L

  • Depth electrode
microTargeting(TM) Electrode, 1x, sterile, R.ZAP, Platform
FHC, INC.
44970R-00259
In Commercial Distribution

  • 10873263002596 ()
  • 00873263002599 ()

  • Length: 205.72 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 220.72 Millimeter
  • Length: 10 Millimeter
44970R

  • Depth electrode
microTargeting(TM) Electrode, 1x, sterile, single, D.ZAP(Z), T=30 for use with Frame and STar or MT Drive
FHC, INC.
34685Z-00254
In Commercial Distribution

  • 10873263002541 ()
  • 00873263002544 ()

  • Length: 256.4 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
34685Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, single, D.ZAP(L), T=30 for use with Frame and STar or MT Drive
FHC, INC.
34685L-00252
In Commercial Distribution

  • 10873263002527 ()
  • 00873263002520 ()

  • Length: 256.4 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
34685L

  • Depth electrode
microTargeting(TM) Electrode, differential, sterile, single, 1 Meg for use with Frame and STar or MT Drive
FHC, INC.
34680R-00250
In Commercial Distribution

  • 10873263002503 ()
  • 00873263002506 ()

  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 256.4 Millimeter
  • Length: 271.4 Millimeter
34680R

  • Depth electrode
microTargeting Array Electrode, 1x, sterile, D.ZAP(L) for use with Frame, STar or MT Drive
FHC, INC.
22675L-00244
In Commercial Distribution

  • 10873263002442 ()
  • 00873263002445 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.55 Millimeter
22675L

  • Depth electrode
microTargeting Array Electrode, sterile, 1 Meg, T=30 for use with Frame, STar or MT Drive
FHC, INC.
22670R-00242
In Commercial Distribution

  • 10873263002428 ()
  • 00873263002421 ()

  • Impedance: Megaohms
  • Length: 261.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
22670R

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(AR)(AR7)-00865
In Commercial Distribution

  • 00873263008652 ()
  • 10873263008659 ()
MTDWZP(AR)(AR7)

  • Depth electrode
microTargeting™ Platform Electrodes 5x Sterile
FHC, INC.
44375Z-00798
In Commercial Distribution

  • 10873263007980 ()
  • 00873263007983 ()

  • Length: 3 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 212.72 Millimeter
  • Length: 220.72 Millimeter
44375Z

  • Depth electrode
microTargeting™ Single Frame Platinum 5X Sterile
FHC, INC.
35385Z-00796
In Commercial Distribution

  • 10873263007966 ()
  • 00873263007969 ()

  • Length: 3 Millimeter
  • Length: 263.4 Millimeter
  • Outer Diameter: 0.86 Millimeter
  • Impedance: Megaohms
  • Length: 271.4 Millimeter
35385Z

  • Depth electrode
microTargeting(TM) Electrode, Back loaded, Platinum/Iridium with Glass Insulation, Presterile
FHC, INC.
MTBPBP(DT1)-00672
In Commercial Distribution

  • 10873263006723 ()
  • 00873263006726 ()

  • Length: 300 Millimeter
  • Length: 10 Millimeter
  • Outer Diameter: 0.63 Millimeter
  • Impedance: Megaohms
MTBPBP(DT1)

  • Depth electrode
microTargeting™ Electrodes, differential, tungsten, sterile, DZAP
FHC, INC.
MTDWZP(SS)(BP8)-00661
In Commercial Distribution

  • 10873263006617 ()
  • 00873263006610 ()

  • Length: 263.4 Millimeter
  • Outer Diameter: 0.7 Millimeter
  • Length: 268.4 Millimeter
  • Impedance: Megaohms
  • Length: 3 Millimeter
MTDWZP(SS)(BP8)

  • Depth electrode
microTargeting™ Electrodes, differential, tungsten, sterile, LZAP
FHC, INC.
MTDWLP(SS)(BP8)-00659
In Commercial Distribution

  • 10873263006594 ()
  • 00873263006597 ()

  • Outer Diameter: 0.7 Millimeter
  • Length: 263.4 Millimeter
  • Length: 3 Millimeter
  • Length: 268.4 Millimeter
  • Impedance: Megaohms
MTDWLP(SS)(BP8)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, sterile
FHC, INC.
MTDWBP(AO)(AO1)-00542
In Commercial Distribution

  • 10873263005429 ()
  • 00873263005422 ()

  • Length: 3 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 1.27 Millimeter
  • Length: 274 Millimeter
  • Length: 282 Millimeter
MTDWBP(AO)(AO1)

  • Depth electrode
microTargeting(TM) Electrode, shielded, tungsten, DZAP(L), sterile
FHC, INC.
MTSWLP(JN)(JN1)-00492
In Commercial Distribution

  • 10873263004927 ()
  • 00873263004920 ()

  • Impedance: Megaohms
  • Length: 251.4 Millimeter
  • Length: 278.4 Millimeter
  • Length: 25 Millimeter
  • Outer Diameter: 0.77 Millimeter
MTSWLP(JN)(JN1)

  • Depth electrode
microTargeting(TM) Electrode, shielded, tungsten, sterile
FHC, INC.
MTSWBP(JN)(JN2)-00490
In Commercial Distribution

  • 10873263004903 ()
  • 00873263004906 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.77 Millimeter
  • Length: 16 Millimeter
  • Length: 288.4 Millimeter
  • Length: 270.4 Millimeter
MTSWBP(JN)(JN2)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(SP)(AR5)-00472
In Commercial Distribution

  • 10873263004729 ()
  • 00873263004722 ()

  • Length: 266.5 Millimeter
  • Length: 5 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 276.5 Millimeter
MTDWZP(SP)(AR5)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(NS)(SL2)-00464
In Commercial Distribution

  • 10873263004644 ()
  • 00873263004647 ()

  • Length: 10 Millimeter
  • Length: 274.65 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
  • Length: 258 Millimeter
MTDWZP(NS)(SL2)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, DZAP(Z), sterile
FHC, INC.
MTDWZP(NS)(SK2)-00462
In Commercial Distribution

  • 10873263004620 ()
  • 00873263004623 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 243.65 Millimeter
  • Length: 227 Millimeter
MTDWZP(NS)(SK2)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, sterile
FHC, INC.
MTDWBP(SB)(SB2)-00390
In Commercial Distribution

  • 10873263003906 ()
  • 00873263003909 ()

  • Length: 260 Millimeter
  • Impedance: Megaohms
  • Length: 6 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 272.65 Millimeter
MTDWBP(SB)(SB2)

  • Depth electrode
microTargeting(TM) Electrode, differential, tungsten, sterile
FHC, INC.
MTDWBP(LS)(LS3)-00388
In Commercial Distribution

  • 10873263003883 ()
  • 00873263003886 ()

  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Outer Diameter: 0.77 Millimeter
  • Length: 291.5 Millimeter
  • Length: 273.5 Millimeter
MTDWBP(LS)(LS3)

  • Depth electrode
microTargeting(TM) Electrode, differential, platinum/iridium, epoxy insulated, sterile, D.ZAP(Z)
FHC, INC.
MTDPZP(EP)(BP7)-00345
In Commercial Distribution

  • 10873263003456 ()
  • 00873263003459 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.86 Millimeter
  • Length: 10 Millimeter
  • Length: 271.4 Millimeter
  • Length: 256.4 Millimeter
MTDPZP(EP)(BP7)

  • Depth electrode
microTargeting(TM) Electrode, differential, sterile, platinum/iridium, glass insulated
FHC, INC.
MTDPBP(LS)(LS3)-00326
In Commercial Distribution

  • 10873263003265 ()
  • 00873263003268 ()

  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 291.5 Millimeter
  • Outer Diameter: 0.86 Millimeter
  • Length: 273.5 Millimeter
MTDPBP(LS)(LS3)

  • Depth electrode
microTargeting™ Electrode, tungsten, sterile, D.ZAP(Z)
FHC, INC.
MTDWZP(AO)(A11)-00921
In Commercial Distribution

  • 10873263009212 ()
  • 00873263009215 ()
MTDWZP(AO)(A11)

  • Depth electrode
microTargeting(TM) Electrode, 6x, differential, tungsten, DZAP(Z), nonsterile
FHC, INC.
MTDWLN(AR)(DU1)-00707
In Commercial Distribution

  • 10873263007072 ()
  • 00873263007075 ()

  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
  • Impedance: Megaohms
  • Length: 271.5 Millimeter
  • Length: 286.5 Millimeter
MTDWLN(AR)(DU1)

  • Depth electrode
microTargeting(TM) Electrode, 6x, differential, tungsten, DZAP(Z), nonsterile
FHC, INC.
MTDWZN(AR)(DU1)-00706
In Commercial Distribution

  • 10873263007065 ()
  • 00873263007068 ()

  • Length: 271.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Length: 10 Millimeter
  • Length: 286.5 Millimeter
  • Impedance: Megaohms
MTDWZN(AR)(DU1)

  • Depth electrode
microTargeting™ Array Frame Platinum 6X Non Sterile
FHC, INC.
25335Z-00791
In Commercial Distribution

  • 10873263007911 ()
  • 00873263007914 ()

  • Outer Diameter: 0.56 Millimeter
  • Length: 276.5 Millimeter
  • Length: 3 Millimeter
  • Length: 268.5 Millimeter
  • Impedance: Megaohms
25335Z

  • Depth electrode
microTargeting™ Array Electrodes 6x Non Sterile
FHC, INC.
22335Z-00789
In Commercial Distribution

  • 10873263007898 ()
  • 00873263007891 ()

  • Length: 3 Millimeter
  • Length: 276.5 Millimeter
  • Length: 268.5 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
22335Z

  • Depth electrode
microTargeting™ Array Frame Platinum 5X Sterile
FHC, INC.
25375Z-00792
In Commercial Distribution

  • 10873263007928 ()
  • 00873263007921 ()

  • Length: 3 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 276.5 Millimeter
  • Length: 268.5 Millimeter
25375Z

  • Depth electrode
microTargeting(TM) Electrode, sterile, 1x, array, D.ZAP(Z) for use with Frame and STar or MT Drive
FHC, INC.
22675Z-00246
In Commercial Distribution

  • 10873263002466 ()
  • 00873263002469 ()

  • Length: 276.5 Millimeter
  • Length: 10 Millimeter
  • Length: 261.5 Millimeter
  • Outer Diameter: 0.55 Millimeter
  • Impedance: Megaohms
22675Z

  • Depth electrode
microTargeting™ Array Electrodes 5x Sterile
FHC, INC.
22375Z-00790
In Commercial Distribution

  • 10873263007904 ()
  • 00873263007907 ()

  • Length: 268.5 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.55 Millimeter
  • Length: 3 Millimeter
  • Length: 276.5 Millimeter
22375Z

  • Depth electrode
Urethral measurement device, female.
VESIFLO INC
March 2017
In Commercial Distribution

  • 00862563003078 ()
203511-SD

  • Intraurethral valve/pump
Urinary prosthesis, female, non-surgical -- Sizing Device
VESIFLO INC
Sep 2016
Not in Commercial Distribution

  • 08625630003034 ()
203511 SD

  • Intraurethral valve/pump
< 1 ... 3 4 5 6 7 ... 45 >