Anterior Cervical Plating System, 4.25mm dia. 20mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-20V
In Commercial Distribution

  • 90814008023847 ()

  • Height: 20 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.75mm dia. 14mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-475-14V
In Commercial Distribution

  • 90814008023809 ()

  • Height: 14 Millimeter
  • Width: 4.75 Millimeter
  • Depth: 4.75 Millimeter
ACP-475-14V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long variable screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12V
In Commercial Distribution

  • 90814008023748 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12V

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4.25mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-425-12F
In Commercial Distribution

  • 90814008023625 ()

  • Height: 12 Millimeter
  • Width: 4.25 Millimeter
  • Depth: 4.25 Millimeter
ACP-425-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3.75mm dia. 12mm long fixed screw. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-375-12F
In Commercial Distribution

  • 90814008023564 ()

  • Height: 12 Millimeter
  • Width: 3.75 Millimeter
  • Depth: 3.75 Millimeter
ACP-375-12F

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-4-80
In Commercial Distribution

  • 90814008023519 ()

  • Height: 80 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-4-80

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 4 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-4-68
In Commercial Distribution

  • 90814008023489 ()

  • Height: 68 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-4-68

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-3-74
In Commercial Distribution

  • 90814008023441 ()

  • Height: 74 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-3-74

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 3 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-3-62
In Commercial Distribution

  • 90814008023403 ()

  • Height: 62 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-3-62

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 2 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-2-51
In Commercial Distribution

  • 90814008023359 ()

  • Height: 51 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter


  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 2 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-2-33
In Commercial Distribution

  • 90814008023298 ()

  • Height: 33 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-2-33

  • Intervertebral-body internal spinal fixation system
Anterior Cervical Plating System, 1 level implant. The Tangis Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with: • degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), • spondylolisthesis, • trauma (i.e. fractures or dislocations), • tumors, • deformity (defined as kyphosis, lordosis, or scoliosis), • pseudarthrosis, • failed previous fusion, • spinal stenosis
NVISION BIOMEDICAL TECHNOLOGIES, INC.
ACP-1-34
In Commercial Distribution

  • 90814008023281 ()

  • Height: 34 Millimeter
  • Width: 17 Millimeter
  • Depth: 1.98 Millimeter
ACP-1-34

  • Intervertebral-body internal spinal fixation system
PLATINUM sEEG DEPTH ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-170-NS
In Commercial Distribution

  • 00650551148722 ()


  • Depth electrode
PLATINUM sEEG ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-169-NS
In Commercial Distribution

  • 00650551148715 ()


  • Depth electrode
PLATINUM sEEG DEPTH ELECTRODE, 16 MACRO CONTACTS, MINI CONNECTOR, 1 EXIT, 1 LEAD, 1 TAIL, NON-STERILE
PMT CORPORATION
2102-16-171-NS
In Commercial Distribution

  • 00650551148739 ()


  • Depth electrode
TROUGH EX0910177 BONE GRAFT
MEDTRONIC SOFAMOR DANEK, INC.
EX0910177
In Commercial Distribution

  • 00613994933423 ()


  • Bone graft packing block
TROUGH EX0810836 BONE GRAFT
MEDTRONIC SOFAMOR DANEK, INC.
EX0810836
In Commercial Distribution

  • 00613994933409 ()


  • Bone graft packing block
PACKING STATION EX0818003 GRAFT
MEDTRONIC SOFAMOR DANEK, INC.
EX0818003
In Commercial Distribution

  • 00763000216948 ()


  • Bone graft packing block
STATION EX0220045 GRAFT PACKING
MEDTRONIC SOFAMOR DANEK, INC.
EX0220045
In Commercial Distribution

  • 00763000371777 ()


  • Bone graft packing block
microTargeting Single Procedure Kit, with microElectrode, tubes, sterile drape sleeve and cable. Contains: IT(BP2): Insertion Tube. 2x MTDWLN(BP)(BP7): microTargeting Electrode. PT(BP2): Protective Tube. Sterile Drape Sleeve for microTargeting motor FC1020 Electrode Lead Individual Specifications: IT(BP2) - 183mm tube length, 1.829mm OD, 1.6mm ID, 184mm stylet (not including collar). MTDWLN(BP)(BP7) - 271.4mm electrode length, 10mm differential, 256.4mm protective tube length, 0.77mm OD. 1Meg DZAP(L) PT(PB2) - 181mm tube length, 1.47mm OD, 0.99mm ID OD: 0.77mm
FHC, INC.
KTF1001-00757
In Commercial Distribution

  • 00873263007570 ()
KTF1001

  • Depth electrode
  • Patient surgical drape, single-use
  • Intracerebral cannula, nonimplantable, single-use