SEARCH RESULTS FOR: Origin(4355 results)

Export results
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

MyoSPECT ES GANTRY
G E MEDICAL SYSTEMS ISRAEL LTD.
H3912AB
In Commercial Distribution

  • 00195278421579 ()
5875815-20

  • Stationary gamma camera system
STARGATE NM GANTRY FINAL
G E MEDICAL SYSTEMS ISRAEL LTD.
H3911AB
In Commercial Distribution

  • 00195278118295 ()


  • Stationary gamma camera system
  • Full-body CT system
Prometra II 40ml Programmable Pump
Flowonix Medical, Inc.
16827
In Commercial Distribution

  • 00810335020242 ()


  • Implantable intrathecal infusion pump, programmable
The Prometra II Programmable Pump is a sterile, battery-operated, teardrop-shaped implantable, programmable infusion pump, with a rigid titanium housing and flow controller system, which dispenses infusate into the intrathecal space through an implanted intrathecal catheter. To help increase safety, the Prometra II Pump incorporates a safety valve (flow-activated valve or FAV) that will shut off drug flow to the patient in the event a high flow rate occurs, such as during an MRI. All functions of the system (e.g., dosing) are controlled externally using a hand-held, battery-operated programmer. The Prometra II Pump contains a metal bellows drug reservoir with a capacity of 20 milliliters (mL). The reservoir propellant is stored within the rigid housing surrounding the bellows and provides the driving pressure for the pump. The driving pressure on the reservoir forces the infusate through an outlet filter (0.22 pm), and into an electronically controlled flow metering valve-accumulator subsystem. The Infumorph passes from the flow metering subsystem, into the catheter access port then into the catheter for delivery to the intrathecal space.
Flowonix Medical, Inc.
13827
In Commercial Distribution

  • 00810335020228 ()


  • Implantable intrathecal infusion pump, programmable
The Prometra Programmable Pump is a sterile, battery-operated, teardrop-shaped implantable, programmable infusion pump, with a rigid titanium housing and flow controller system, which dispenses infusate into the intrathecal space through an implanted intrathecal catheter.
Flowonix Medical, Inc.
11827
In Commercial Distribution

  • 00810335020082 ()


  • Implantable intrathecal infusion pump, programmable
CryoTip
FUJIFILM IRVINE SCIENTIFIC, INC.
40709-Pack
In Commercial Distribution

  • 00893727002118 ()
  • 10893727002115 ()
40709

  • Assisted reproduction cryotube
microTargeting™ Platform Platinum 6X Non Sterile
FHC, INC.
45335Z-00799
In Commercial Distribution

  • 10873263007997 ()
  • 00873263007990 ()

  • Length: 212.72 Millimeter
  • Impedance: Megaohms
  • Length: 3 Millimeter
  • Outer Diameter: 0.56 Millimeter
  • Length: 220.72 Millimeter
45335Z

  • Depth electrode
microTargeting(TM) Electrode, 6x, non-sterile, for use with Nexframe(R) and STar Drive
FHC, INC.
5730R-00579
In Commercial Distribution

  • 10873263005795 ()
  • 00873263005798 ()

  • Outer Diameter: 0.56 Millimeter
  • Impedance: Megaohms
  • Length: 10 Millimeter
  • Length: 242.2 Millimeter
  • Length: 227.2 Millimeter
5730R

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, DZAP(L), for use with Nexframe(R)
FHC, INC.
5035L-00576
In Commercial Distribution

  • 10873263005764 ()
  • 00873263005767 ()

  • Length: 234.2 Millimeter
  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
5035L

  • Depth electrode
microTargeting(TM) Electrode, non-sterile, for use with Nexframe(R)
FHC, INC.
5030R-00575
In Commercial Distribution

  • 10873263005757 ()
  • 00873263005750 ()

  • Impedance: Megaohms
  • Outer Diameter: 0.56 Millimeter
  • Length: 10 Millimeter
  • Length: 249.2 Millimeter
  • Length: 234.2 Millimeter
5030R

  • Depth electrode
< 1 ... 272 273 274 275 276 ... 436 >