DEVICE: VASCU-GUARD Peripheral Vascular Patch (00085412530925)

Device Identifier (DI) Information

VASCU-GUARD Peripheral Vascular Patch
VG0209N
In Commercial Distribution
VG0209N
SYNOVIS LIFE TECHNOLOGIES, INC.
00085412530925
GS1

1
017415781 *Terms of Use
VASCU-GUARD Peripheral Vascular Patch is prepared from bovine pericardium which is cross-linked with glutaraldehyde. The pericardium is procured from cattle originating in the United States. VASCU-GUARD Peripheral Vascular Patch is chemically sterilized using ethanol and propylene oxide. VASCU-GUARD Peripheral Vascular Patch has been treated with 1 molar sodium hydroxide for a minimum of 60 minutes at 20 - 25°C. VASCU-GUARD Peripheral Vascular Patch is packaged in a container filled with sterile, non-pyrogenic water containing propylene oxide. The contents of the unopened, undamaged container are sterile.
CLOSE

Device Characteristics

MR Safe
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. The copyright and database rights in the original GMDN materials are owned by The GMDN Agency Ltd 2005-2023. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35273 Cardiovascular patch, animal-derived
An implantable material designed to reinforce suture lines and/or increase the strength of weak or injured cardiac and/or peripheral vascular tissues during cardiovascular repair/reconstruction procedures (e.g., annulus or septal defect repair, endarterectomy, profundaplasty). It is a patch made of, or coated/impregnated with, materials of animal origin (e.g., porcine, bovine, or equine pericardium/collagen), that is typically implanted with sutures.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DXZ PATCH, PLEDGET AND INTRACARDIAC, PETP, PTFE, POLYPROPYLENE
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Special Storage Condition, Specify: Do not freeze.
Storage Environment Temperature: between 20 and 25 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

3e79a953-40ca-4910-af71-cf052f080de3
July 27, 2023
6
October 08, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)933-0303
Medinfo_medproducts@baxter.com
CLOSE