DEVICE: Flo-Rester® Disposable Internal Vessel Occluder (00085412531984)
Device Identifier (DI) Information
Flo-Rester® Disposable Internal Vessel Occluder
50300
In Commercial Distribution
50300
SYNOVIS LIFE TECHNOLOGIES, INC.
50300
In Commercial Distribution
50300
SYNOVIS LIFE TECHNOLOGIES, INC.
Flo-Rester is a sterile, single use, disposable occluder composed of two silicone rubber bulbs on the distal ends of a flexible shaft. A tab on a tether is attached to the midpoint of the flexible shaft forming a T configuration. Flo-Rester bulbs and tab are radiopaque.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
47110 | Intravascular anastomosis occluder |
A device designed to temporarily occlude the flow of blood in the lumen of a blood vessel at a vascular anastomosis, primarily to control bleeding and enable operative field visualization during coronary or peripheral vascular bypass grafting and vessel repair surgery. It is typically designed as a flexible shaft with dilated/bulbous ends that is entirely inserted into the vessel lumen via a small incision at the surgical site to arrest blood flow at the anastomosis; it will typically have an external tab or tether used for its removal. It is typically made of silicone elastomer and polyester radiopaque materials and is available in a range of diameters. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DXC | CLAMP, VASCULAR |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K883696 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
c4a3e0ca-eb28-46d8-9c0f-34ed306e90fe
February 19, 2021
4
September 24, 2016
February 19, 2021
4
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
50085412531989 | 5 | 00085412531984 | In Commercial Distribution | CASE |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)933-0303
Medinfo_medproducts@baxter.com
Medinfo_medproducts@baxter.com