DEVICE: Ambler Surgical (00190660038625)
Device Identifier (DI) Information
Ambler Surgical
Allis grasping forceps
In Commercial Distribution
96-356
AMBLER SURGICAL CORP.
Allis grasping forceps
In Commercial Distribution
96-356
AMBLER SURGICAL CORP.
Allis grasping forceps, non-rotatable, double-action, 5.0mm diameter, 330.0mm working length, straight tips, 1x2 teeth, serrated jaws, carbon fiber ring handle with ratchet, HF connection
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
35080 | Rigid endoscopic tissue manipulation forceps, reusable |
A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proximal controls (e.g., scissors-like handles), a rigid long slender shaft, and distal grasping jaws; it is not an electrosurgical device and is not dedicated to biopsy. This is a reusable device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEN | FORCEPS, GENERAL & PLASTIC SURGERY |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
33bda48e-924e-461f-8d0e-26ec9f040378
January 12, 2021
1
January 04, 2021
January 12, 2021
1
January 04, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(888)407-0006
0
sales@amblersurgical.com
sales@amblersurgical.com