DEVICE: Ambler Surgical (00190660167578)
Device Identifier (DI) Information
Ambler Surgical
Metzenbaum scissors
In Commercial Distribution
98-154
AMBLER SURGICAL CORP.
Metzenbaum scissors
In Commercial Distribution
98-154
AMBLER SURGICAL CORP.
Metzenbaum scissors, double-action, non-rotatable, 5.0mm diameter, 330.0mm working length, medium, slightly curved 15.0mm TC blades, blunt tips, carbon fiber ring handle, HF connection
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46421 | Rigid endoscopic scissors, reusable |
A hand-held rigid device used in combination with a dedicated endoscope and intended to cut tissue or sutures during an endoscopic procedure. It is typically constructed of stainless steel and is designed as a long pair of parallel sliding arms whose distal end is equipped with a pair of mechanical (i.e., not electrosurgical) cutting blades operated through a ringed handle at the proximal end. It is typically introduced into the body cavity through the working channel of the endoscope. This is a reusable device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEI | Electrosurgical, cutting & coagulation & accessories |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
8932dd7a-d89a-4218-96bd-74d828538df4
January 12, 2021
1
January 04, 2021
January 12, 2021
1
January 04, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(888)407-0006
0
sales@amblersurgical.com
sales@amblersurgical.com