🚩 DEVICE: Javelin Peripheral IVL Catheter (00195451000799)
Device Identifier (DI) Information
Javelin Peripheral IVL Catheter
Javelin Peripheral IVL Catheter
In Commercial Distribution
JVNPIVLF
Shockwave Medical, Inc.
Javelin Peripheral IVL Catheter
In Commercial Distribution
JVNPIVLF
Shockwave Medical, Inc.
The IVL Catheter is a proprietary lithotripsy device delivered through the peripheral arterial system of the lower extremities to the site of an otherwise difficult to treat calcified stenosis. Intravascular Lithotripsy (IVL) is an interventional procedure that utilizes a fluid-filled catheter connected to power sources that generate acoustic shock waves; the shock waves modify calcified plaque in peripheral arteries. Energizing the intravascular lithotripsy device will generate acoustic pressure pulses within the target treatment site, disrupting calcium within the lesion.
The Shockwave Intravascular Lithotripsy (IVL) System with the Shockwave Javelin Peripheral Intravascular Lithotripsy (IVL) Catheter consists of three main components: the IVL Catheter, the IVL Generator, and the IVL Connector Cable. The Shockwave Javelin IVL Catheter is comprised of a catheter with an integrated emitter located near the distal end to enable the localized delivery of acoustic pressure pulses in the peripheral vasculature. The emitter is radiopaque to facilitate catheter visibility under fluoroscopy and is surrounded by a fluid-filled space (IVL window) that allows for the transmission of acoustic pressure pulses.
The Shockwave Javelin Peripheral IVL Catheter shaft contains a lumen to pressurize and a lumen to de-pressurize the catheter with saline (the medium to create IVL), a guidewire lumen, and a lithotripsy emitter. The emitter is enclosed within a non-expandable polymer fluid-filled space (i.e., IVL window) containing saline that is connected to the proximal shaft, inlet and outlet ports, and is tapered down to the distal tip of the catheter. The IVL window is located near the distal tip of the catheter. The emitter is radiopaque to facilitate catheter visibility under fluoroscopy and is surrounded by the IVL window that allows for the transmission of acoustic pressure pulses. The IVL window is designed to provide a static catheter profile.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
66729 | Intravascular lithotripsy system balloon catheter, peripheral |
An electrically-powered, flexible tube intended to be introduced into a peripheral artery stiffened by a highly calcified atheromatous plaque, to transmit ultrasound (US) waves [e.g., acoustic pressure pulses] for the disruption of the plaque to improve vessel compliance. It is used in conjunction with a dedicated control unit/generator (not included) and includes transducers intended to convert electrical energy to ultrasound and an inflatable balloon at its distal end to facilitate energy transmission and dilation of the vessel. This is a single-use device.
|
Active | false |
12535 | Medical equipment/instrument drape, single-use |
A flexible polymer sheet/bag/sleeve designed to form a protective water-resistant enclosure around a piece of medical equipment/instrument (e.g., C-arm, surgical laser/camera/microscope, examination table/chair) and/or components (e.g., cables, tubes, headrest). It is intended as a hygienic barrier to protect the equipment/instrument from soiling and/or contamination when used inside, or within the vicinity of, a hygienic area; it may have patient contact, however it is not intended to be introduced into a body cavity (noninvasive). It is neither a dedicated handle cover, device cap nor an ultrasound transducer cover. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
PPN | Percutaneous Catheter, Ultrasound |
OEZ | Cardiovascular Procedure Kit |
JAA | System, X-Ray, Fluoroscopic, Image-Intensified |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K242213 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Keep away from sunlight, keep dry |
Clinically Relevant Size
[?]Size Type Text |
---|
Outer Diameter: 1.5 Millimeter |
Catheter Working Length: 150 Centimeter |
Introducer Sheath Compatibility: 5 French |
Guidewire Diameter: 0.014 Inch |
Device Record Status
8d886d72-7a6d-491e-926a-95c4cd4a8b93
October 17, 2024
1
October 09, 2024
October 17, 2024
1
October 09, 2024
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1-877-775-4846
cs@shockwavemedical.com
cs@shockwavemedical.com