DEVICE: Albertsons (00321130351115)
Device Identifier (DI) Information
Albertsons
Digital Wide-Tip Pregnancy Test
In Commercial Distribution
N/A
BETTER LIVING BRANDS LLC
Digital Wide-Tip Pregnancy Test
In Commercial Distribution
N/A
BETTER LIVING BRANDS LLC
Albertsons DPS DIG Wide-Tip Blue
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| Yes | |
| No | |
| Yes | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 33819 | Total human chorionic gonadotropin IVD, kit, rapid ICT, clinical |
A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of total human chorionic gonadotropin (HCG), which includes a combination of intact HCG, nicked HCG, alpha-HCG subunits, and beta-HCG subunits, in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses to aid detection of pregnancy, or as a predictor of adverse pregnancy outcomes (e.g., miscarriage) and/or trisomy 21 (Down syndrome). It is not intended to be used for self-testing.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| LCX | Kit, Test, Pregnancy, Hcg, Over The Counter |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K060128 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Storage Environment Temperature: between 2 and 30 Degrees Celsius |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| No Device Sizes |
Device Record Status
adc9bdbd-c450-46b4-ae51-4495546fb43a
March 11, 2025
1
March 03, 2025
March 11, 2025
1
March 03, 2025
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| 10321130351112 | 24 | 00321130351115 | In Commercial Distribution | Shipper |
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
00633472000072
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1-800-899-7353
xx@xx.xx
xx@xx.xx