DEVICE: ReliOn BP300W Wrist Blood Pressure Monitor (00605388577221)
Device Identifier (DI) Information
ReliOn BP300W Wrist Blood Pressure Monitor
6021RELN2
In Commercial Distribution
WAL-MART STORES, INC.
6021RELN2
In Commercial Distribution
WAL-MART STORES, INC.
No description.
Device Characteristics
MR Unsafe | |
No | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
45617 | Automatic-inflation electronic sphygmomanometer, portable, arm/wrist |
An electrically-powered device designed to noninvasively measure blood pressure using a self-contained software program that regulates automatic arm/wrist-cuff inflation and measurement cycles. It typically displays current heart rate and mean arterial pressure in addition to systolic and diastolic blood pressures; it may have memory to store blood pressure values and may sound an alarm if blood pressure exceeds pre-set limits. This device is designed to be portable (e.g., hand-held or carried in a pouch) and is often used for emergency services or home blood pressure monitoring.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DXN | System, Measurement, Blood-Pressure, Non-Invasive |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K131742 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
Storage Environment Humidity: between 10 and 95 Percent (%) Relative Humidity |
Storage Environment Temperature: between -20 and 60 Degrees Celsius |
Storage Environment Temperature: between -4 and 140 Degrees Fahrenheit |
Handling Environment Humidity: between 15 and 90 Percent (%) Relative Humidity |
Handling Environment Temperature: between 10 and 40 Degrees Celsius |
Handling Environment Temperature: between 50 and 104 Degrees Fahrenheit |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
02a58c49-06f2-4b46-a131-2eca48322293
November 08, 2019
4
September 20, 2016
November 08, 2019
4
September 20, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
10605388577228 | 10 | 00605388577221 | In Commercial Distribution | Case |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1-855-776-0662
XX@XX.XX
XX@XX.XX