DEVICE: Alexis Wound Protector-Retractor (00607915117245)

Device Identifier (DI) Information

Alexis Wound Protector-Retractor
C8312
In Commercial Distribution

APPLIED MEDICAL RESOURCES CORPORATION
00607915117245
GS1

1
187129135 *Terms of Use
Wound Retractor and Protector
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
47431 Radial surgical retractor
A sterile surgical device intended to be inserted across a surgical incision to separate the margins of the incision to create a conduit to the underlying organs/tissues during hand-assisted minimally-invasive and open surgery. It consists of an external and internal fixed or retracting ring interconnected with an elastomeric sleeve/sheath intended to also provide protection against wound contamination, and may include channels/tubing to allow wound-edge irrigation. Also known as a lap disc, hand access device, handport, or protector, it may be used with or without a seal cap for colorectal, urological, gynaecological, or general abdominal surgical procedures. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KGW Ring (Wound Protector), Drape Retention, Internal
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: 2-4 cm
CLOSE

Device Record Status

891fddbb-1a2c-4755-a603-486efb0390ac
September 04, 2024
3
September 24, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
10607915117242 5 00607915117245 In Commercial Distribution
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
1.949.713.8300
contact@appliedmedical.com
CLOSE