DEVICE: Ready Sensor™ GOLD Reference Sensor Inner Element (00630414115030)
Device Identifier (DI) Information
Ready Sensor™ GOLD Reference Sensor Inner Element
10329947
In Commercial Distribution
478509
Siemens Healthcare Diagnostics Inc.
10329947
In Commercial Distribution
478509
Siemens Healthcare Diagnostics Inc.
Ready Sensor™ GOLD Replacement reference Sensor Inner Element. An in vitro diagnostics device.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
59238 | Ion selective electrode (ISE) reference solution IVD, reagent |
A substance or reactant intended to be used together with a reference electrode to perform a specific function in an assay that is used for the quantitative measurement of one or multiple electrolytes in a clinical specimen.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
JGS | ELECTRODE, ION SPECIFIC, SODIUM |
CEM | ELECTRODE, ION SPECIFIC, POTASSIUM |
CHL | ELECTRODE MEASUREMENT, BLOOD-GASES (PCO2, PO2) AND BLOOD PH |
CGZ | ELECTRODE, ION-SPECIFIC, CHLORIDE |
JFP | ELECTRODE, ION SPECIFIC, CALCIUM |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K962021 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Do not freeze. Keep away from sunlight |
Storage Environment Temperature: between 4 and 25 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
102b2656-8f3e-4a2c-972a-cfc1ee5249b7
November 19, 2021
5
September 24, 2016
November 19, 2021
5
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(877)229-3711
CONTACT@SIEMENS-HEALTHINEERS.COM
CONTACT@SIEMENS-HEALTHINEERS.COM