DEVICE: Multistix® 7 Reagent Strips (00630414549040)

Device Identifier (DI) Information

Multistix® 7 Reagent Strips
10326145
In Commercial Distribution
A2165C16
Siemens Healthcare Diagnostics Inc.
00630414549040
GS1

100
064608573 *Terms of Use
Siemens Healthcare Diagnostics Reagent Strips for Urinalysis include test pads for protein, blood, leukocytes, nitrite, glucose, ketone (acetoacetic acid) and pH.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
54514 Multiple urine analyte IVD, kit, rapid colorimetric, clinical
A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of urine for multiple analytes within a short period relative to standard laboratory testing procedures, using a rapid colorimetric method. This is a rapid test commonly used in the laboratory or in point-of-care analyses to screen for non-microbial markers associated with a urinary tract infection (UTI) [e.g., leukocytes, blood, nitrites, proteins]. It is not intended to be used for self-testing.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
CDM DIAZONIUM COLORIMETRY, UROBILINOGEN (URINARY, NON-QUANT.)
JIN NITROPRUSSIDE, KETONES (URINARY, NON-QUANT.)
JRE REFRACTOMETER FOR CLINICAL USE
JFY ENZYMATIC METHOD, CREATININE
JIR INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.)
JMT DIAZO (COLORIMETRIC), NITRITE (URINARY, NON-QUANT)
JIL METHOD, ENZYMATIC, GLUCOSE (URINARY, NON-QUANTITATIVE)
LJX TEST, URINE LEUKOCYTE
JIO BLOOD, OCCULT, COLORIMETRIC, IN URINE
JJB AZO-DYES, COLORIMETRIC, BILIRUBIN & ITS CONJUGATES (URINARY, NON-QUANT.)
CEN DYE-INDICATOR, PH (URINARY, NON-QUANT.)
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K992257 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Special Storage Condition, Specify: Do not store in direct sunlight.
Storage Environment Temperature: between 15 and 30 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

a9544b7d-48c7-4b44-8567-5ae7744e1b0d
November 28, 2022
7
September 24, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 00630414009582 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(877)229-3711
CONTACT@SIEMENS-HEALTHINEERS.COM