DEVICE: CLINITEK Novus® Automated Urine Chemistry Analyzer (00630414981147)
Device Identifier (DI) Information
CLINITEK Novus® Automated Urine Chemistry Analyzer
10697937
In Commercial Distribution
10697937
Siemens Healthcare Diagnostics Inc.
10697937
In Commercial Distribution
10697937
Siemens Healthcare Diagnostics Inc.
The CLINITEK Novus® Automated Urine Chemistry analyzer is a fully automated urinalysis instrument for clinical laboratory use. The CLINITEK Novus Analyzer is intended to read Siemens Healthcare Diagnostics CLINITEK Novus cassettes, as well as determine urine specific gravity and urine clarity. The CLINITEK Novus cassettes are intended for the semi-quantitative measurement of the following parameters in urine: albumin, bilirubin, blood (occult), creatinine, glucose, ketone (acetoacetic acid), leu
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
35918 | Urine analyser IVD, laboratory |
An electrically-powered automated or semi-automated laboratory instrument intended to be used for the qualitative and/or quantitative in vitro determination of various chemical and cellular constituents of a clinical urine specimen, which typically include bilirubin, glucose, haemoglobin, ketones, nitrites, pH, protein, urobilinogen, specific gravity, blood, red cells, white cells, casts, crystals, sperm, and/or microorganisms (e.g., bacteria). The device uses technology which may include electrical impedance, conductivity, enzyme spectrophotometry, nephelometry and/or photometry.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
JIR | INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.) |
JIN | NITROPRUSSIDE, KETONES (URINARY, NON-QUANT.) |
JRE | REFRACTOMETER FOR CLINICAL USE |
JJB | AZO-DYES, COLORIMETRIC, BILIRUBIN & ITS CONJUGATES (URINARY, NON-QUANT.) |
JMT | DIAZO (COLORIMETRIC), NITRITE (URINARY, NON-QUANT) |
CEN | DYE-INDICATOR, PH (URINARY, NON-QUANT.) |
JIL | METHOD, ENZYMATIC, GLUCOSE (URINARY, NON-QUANTITATIVE) |
KQO | AUTOMATED URINALYSIS SYSTEM |
CDM | DIAZONIUM COLORIMETRY, UROBILINOGEN (URINARY, NON-QUANT.) |
JIO | BLOOD, OCCULT, COLORIMETRIC, IN URINE |
JIX | CALIBRATOR, MULTI-ANALYTE MIXTURE |
LJX | TEST, URINE LEUKOCYTE |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K140717 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -20 and 65 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
be4f0e02-227c-4d5b-8eab-ab0637f85cf6
September 16, 2022
6
September 24, 2016
September 16, 2022
6
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(877)229-3711
CONTACT@SIEMENS-HEALTHINEERS.COM
CONTACT@SIEMENS-HEALTHINEERS.COM