DEVICE: Durepair® (00643169063853)
Device Identifier (DI) Information
Durepair®
62100
Not in Commercial Distribution
MEDTRONIC PS MEDICAL, INC.
62100
Not in Commercial Distribution
MEDTRONIC PS MEDICAL, INC.
DURA 62100 SUBSTITUTE DUREPAIR 2X2IN NCE
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
45829 | Dura mater graft, bovine |
A xenograft made from bovine dura mater or bovine pericardium used for the repair or replacement of the dura mater in a recipient during a neurosurgical procedure. Restoration of the dura mater maintains the integrity of the brain and spinal cord, and helps prevent leakage of the cerebrospinal fluid (CSF). This dural graft is typically overlaid on the patient's dura and resorbs within 9 to 12 months after surgery. It may be supplied in strips of various sizes and shapes (e.g., square or rectangular) and in a sterile, dry state with treated surfaces.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GXQ | DURA SUBSTITUTE |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K063117 | 000 |
K161370 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 2 and 30 Degrees Celsius |
Special Storage Condition, Specify: Keep away from heat sources |
Clinically Relevant Size
[?]Size Type Text |
---|
Width: 5.0 Centimeter |
Length: 5.0 Centimeter |
Device Record Status
7ea66f25-867c-43f4-9205-b7b926d718a2
November 12, 2024
5
June 24, 2015
November 12, 2024
5
June 24, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)633-8766
Corporate.UDI@medtronic.com
Corporate.UDI@medtronic.com