DEVICE: Freezor® MAX (00643169450356)

Device Identifier (DI) Information

Freezor® MAX
229F3
Not in Commercial Distribution

MEDTRONIC, INC.
00643169450356
GS1
June 21, 2018
1
006261481 *Terms of Use
CATH 229F3 FREEZOR MAX3 SURGICAL MED 9F
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
60720 Cardiac cryosurgical system catheter
A sterile, flexible device intended to be used as part of a cardiac tissue cryosurgical system to cryogenically ablate areas of the endocardium of a beating heart in the treatment of cardiac arrhythmias. It is intended to be introduced into the heart via venous access (e.g., femoral vein) and deliver pressurized liquid refrigerant (e.g., nitrous oxide) to its distal cooling segment to achieve extremely low temperatures through gas expansion; it typically includes sensors (e.g., temperature monitoring). This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LPB Cardiac ablation percutaneous catheter
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
P020045 055
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Humidity: less than 85 Percent (%) Relative Humidity
Storage Environment Temperature: between 59 and 86 Degrees Fahrenheit
Handling Environment Temperature: between -31 and 136 Degrees Fahrenheit
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Curve length 55 mm
Length: 90.0 Centimeter
Device Size Text, specify: Tip length 8 mm
Device Size Text, specify: Shaft size 9 Fr
CLOSE

Device Record Status

ca34762a-3be8-4e73-bf82-c12c8a1bd537
July 06, 2018
4
December 01, 2014
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
+1(800)633-8766
Corporate.UDI@medtronic.com
CLOSE