DEVICE: EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE (THV) (00690103194364)
Device Identifier (DI) Information
EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE (THV)
9600TFX
In Commercial Distribution
9600TFX29A
Edwards Lifesciences LLC
9600TFX
In Commercial Distribution
9600TFX29A
Edwards Lifesciences LLC
EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE (29MM)
Device Characteristics
MR Conditional | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
60247 | Pulmonary transcatheter heart valve bioprosthesis |
An implantable xenograft (e.g., bovine, porcine) intended to be used to repair/replace a stenosed or regurgitant pulmonary heart valve prosthesis (previously implanted), or native pulmonary valve anatomy that may have been surgically repaired, and which is designed to be implanted with a catheter via vascular access. It may be attached to an expandable metal framework which may be expanded with a balloon or self-expand, and may include other material types (e.g., synthetic polymer). Devices associated with implantation (e.g., catheter, introducer) may be included.
|
Active | true |
60245 | Aortic transcatheter heart valve bioprosthesis, stent-like framework |
An implantable xenograft (e.g., bovine, porcine) intended to be used to repair/replace a stenosed and/or regurgitant aortic heart valve, or previously-implanted aortic heart valve prosthesis, and which is designed to be implanted with a catheter via transarterial access (e.g., femoral, subclavian, aortic) or transapical access while the heart is beating. It is comprised of the xenograft, processed to render the tissue non-viable, attached to an expandable metal framework, which is implanted with an included catheter, and when in situ, may be expanded with a balloon or self-expand. Typically devices associated with implantation (e.g., catheter, introducer) are included.
|
Active | true |
58865 | Vascular catheter introduction set, nonimplantable |
A collection of nonimplantable, invasive devices intended to provide percutaneous vascular access to enable introduction of a catheter (not included) into the vascular system. It includes a non-steerable introducer sheath with an inner obturator/dilator, and typically an additional access device(s) [e.g., guidewire, introducer needle, syringe, additional dilators] which may include a haemostatic valve to control blood loss, usually to enable arterial access. This is a single-use device.
|
Active | false |
60246 | Mitral transcatheter heart valve bioprosthesis |
An implantable xenograft (e.g., bovine) intended to be used to repair/replace a stenosed or regurgitant mitral heart valve, or previously-implanted mitral heart valve prosthesis, and which is implanted with a catheter via percutaneous access (e.g., transfemoral, transapical) while the heart is beating. It is comprised of the xenograft, processed to render the tissue non-viable, attached to a metal framework (which may be covered with a synthetic polymer material) that is expandable in situ; it may also include a synthetic polymer subannular valve anchoring component. Devices to assist implantation (e.g., catheter, introducer) are typically included.
|
Active | true |
16463 | Basic crimper |
A hand-held manual device designed to compress (pinch) a non-patient-contact sealing device (e.g., a clip or crimping ring of metal applied apart from the body) to reduce its size (diameter) and create a tight seal on objects being clamped or held together. This is performed by the application of force on the grip of the crimper's handles by the operator. This is a reusable device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
NPU | Prosthesis, Mitral Valve, Percutaneously Delivered |
NPT | Aortic valve, prosthesis, percutaneously delivered |
NPV | Pulmonary Valve Prosthesis Percutaneously Delivered |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 10 and 25 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
Device Size Text, specify: 29 MM |
Device Record Status
a8a9aa1f-f3a0-4ce2-84d3-79a94e5eedda
March 20, 2024
12
July 05, 2015
March 20, 2024
12
July 05, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)822-9637
tech_support@edwards.com
tech_support@edwards.com