DEVICE: THE EDWARDS SAPIEN 3 VALVE WITH ALTERRA ADAPTIVE PRESTENT SYSTEM (00690103210866)
Device Identifier (DI) Information
THE EDWARDS SAPIEN 3 VALVE WITH ALTERRA ADAPTIVE PRESTENT SYSTEM
29AP4045
In Commercial Distribution
29AP4045A
Edwards Lifesciences LLC
29AP4045
In Commercial Distribution
29AP4045A
Edwards Lifesciences LLC
ALTERRA ADAPTIVE PRESTENT SYSTEM (US) 40MM X 48MM
Device Characteristics
MR Conditional | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
60247 | Pulmonary transcatheter heart valve bioprosthesis |
An implantable xenograft (e.g., bovine, porcine) intended to be used to repair/replace a stenosed or regurgitant pulmonary heart valve prosthesis (previously implanted), or native pulmonary valve anatomy that may have been surgically repaired, and which is designed to be implanted with a catheter via vascular access. It may be attached to an expandable metal framework which may be expanded with a balloon or self-expand, and may include other material types (e.g., synthetic polymer). Devices associated with implantation (e.g., catheter, introducer) may be included.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
NPV | Pulmonary Valve Prosthesis Percutaneously Delivered |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
P200015 | 011 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
3241c6d4-749c-45b7-94dd-d6c60fe5fb68
December 31, 2021
1
December 23, 2021
December 31, 2021
1
December 23, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)822-9637
tech_support@edwards.com
tech_support@edwards.com