DEVICE: AimStrip Tandem Lipid Profile and glucose measuring system (00695684773014)
Device Identifier (DI) Information
AimStrip Tandem Lipid Profile and glucose measuring system
ILM-0001A
In Commercial Distribution
GERMAINE LABORATORIES, INC
ILM-0001A
In Commercial Distribution
GERMAINE LABORATORIES, INC
Lipid and Glucose Measuring System
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
52849 | Glucose/ketone/lipid profile IVD, kit, enzyme chemiluminescence |
A collection of reagents and other associated materials intended to be used together to produce a profile consisting of one or multiple clinical chemistry analytes which may include glucose, ketones and/or a lipid profile, using an enzyme chemiluminescence method.
|
Obsolete | false |
53303 | Glucose IVD, kit, electrometry |
A collection of reagents and other associated materials intended to be used for the quantitative measurement of glucose in a clinical specimen, using an electrometry method.
|
Active | false |
41819 | Glucose IVD, control |
A material which is used to verify the performance of an assay intended to be used for the quantitative measurement of glucose in a clinical specimen.
|
Active | false |
53359 | Total cholesterol lipid IVD, kit, spectrophotometry |
A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of total cholesterol lipid in a clinical specimen, using a spectrophotometry method.
|
Active | false |
44697 | Total cholesterol lipid IVD, control |
A material which is used to verify the performance of an assay intended to be used for the quantitative measurement of total cholesterol lipid in a clinical specimen.
|
Active | false |
44701 | Triglyceride IVD, control |
A material which is used to verify the performance of an assay intended to be used for the quantitative measurement of triglycerides in a clinical specimen.
|
Active | false |
53460 | Triglyceride IVD, kit, spectrophotometry |
A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of triglycerides in a clinical specimen, using a spectrophotometry method.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
CGA | Glucose Oxidase, Glucose |
JJX | Single (Specified) Analyte Controls (Assayed And Unassayed) |
CHH | Enzymatic Esterase--Oxidase, Cholesterol |
JGY | Colorimetric Method, Triglycerides |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
4efcb199-ffff-49f3-97c5-f29659b56c41
November 11, 2024
4
March 13, 2020
November 11, 2024
4
March 13, 2020
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1-800-854-8446
sales@germainelabs.com
sales@germainelabs.com