DEVICE: Venti-Scan (00718175001912)
Device Identifier (DI) Information
Venti-Scan
177-091
In Commercial Distribution
177-091
BIODEX MEDICAL SYSTEMS, INC.
177-091
In Commercial Distribution
177-091
BIODEX MEDICAL SYSTEMS, INC.
Venti-Scan disposable, 12" tubing
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
16784 | Radioaerosol administration set |
A collection of devices used to quickly deliver radioaerosol to a patient for ventilatory pulmonary scintigraphy. It is used with an aerosol pump/nebulizer or a compressed air line to generate the radioactive aerosol, and a lead (Pb) protective container to hold the radioactive solution during the inhalation procedure. It typically consists of one or several one-way valves to direct the flow of aerosol to the patient, transport tubing to carry the aerosol to the patient, a mouthpiece, and a bacteria filter to trap any exhaled aerosol. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
IYT | System, Rebreathing, Radionuclide |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K871868 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
82a7f48e-8a22-411d-bcd8-ec872f8649c6
July 06, 2018
3
November 02, 2016
July 06, 2018
3
November 02, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
30718175001944 | 50 | 00718175001912 | In Commercial Distribution | Box | |
20718175001930 | 25 | 00718175001912 | In Commercial Distribution | Box | |
10718175001926 | 10 | 00718175001912 | In Commercial Distribution | Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE