DEVICE: Soft-Cell PC Dialysis Catheter Kit 12.5 F x 12 cm (00801741012389)
Device Identifier (DI) Information
Soft-Cell PC Dialysis Catheter Kit 12.5 F x 12 cm
5533120
Not in Commercial Distribution
5533120
Bard Access Systems, Inc.
5533120
Not in Commercial Distribution
5533120
Bard Access Systems, Inc.
SOFT-CELL DIALYSIS CATH, PC, DL, 12.5 FR. 12cm
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
37278 | Double-lumen haemodialysis catheter, implantable |
An implantable, flexible, double-lumen tube intended to be used for chronic or long-term (> 30 days) vascular access, primarily during haemodialysis, to conduct blood from a patient and returning it after extracorporeal circulation; it may also be used during haemoperfusion and/or apheresis. It is intended for coaxial flow of blood, may be radiopaque, coated with heparin to prevent thrombus formation, and/or include a silver-coated sleeve to retard bacterial growth; devices dedicated to catheter introduction/function (e.g., introducer needle) may be included.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LFJ | CATHETER, SUBCLAVIAN |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 12 Centimeter |
Catheter Gauge: 12.5 French |
Device Record Status
40838eef-f10c-440a-88a7-9b2fbffd9ce0
December 19, 2024
5
May 29, 2017
December 19, 2024
5
May 29, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
10801741012386 | 5 | 00801741012389 | 2024-06-27 | Not in Commercial Distribution | CA |
20801741012383 | 10 | 10801741012386 | 2024-06-27 | Not in Commercial Distribution | BX |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)545-0890
medical.services@crbard.com
medical.services@crbard.com