DEVICE: AuST Steerable Sheath (00810024672004)

Notice: Any discrepancies with this record compared to the label?
If so, send a picture of the label to GUDIDSupport@fda.hhs.gov.

Device Identifier (DI) Information

AuST Steerable Sheath
0-132H-H5074SAN0-SNSP0
In Commercial Distribution

CENTERPOINT SYSTEMS LLC
00810024672004
GS1

1
117126091 *Terms of Use
The AuST Steerable Sheath is intended for the introduction of diagnostic and therapeutic devices into human vasculature, including but not limited to intracardiac, renal or other peripheral placements. Do not use this device for neural placements.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
17846 Vascular guide-catheter, single-use
A flexible tube intended to be used for the percutaneous transluminal passage and placement of a diagnostic/interventional catheter, lead (e.g., pacing lead, balloon dilatation catheter), needle or guidewire through its lumen(s), within the vascular system. It may be rigid or flexible, non-steerable or steerable, single or multiple lumen(s), and the distal section can have a variety of preformed shapes (e.g., straight, hockey stick). It is not intended solely for infusion, is not intended to access superselective small vessels, and does not include a transseptal needle. It may include a disposable percutaneous introduction set or shaft visualization electrodes. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DYB Introducer, Catheter
DRA Catheter, Steerable
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K251051 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Catheter Inner Diameter, French Size = 13.2F
Device Size Text, specify: Outer Diameter, French Size = 17F
Catheter Working Length: 74 Centimeter
Device Size Text, specify: Distal Deflection Diameter, Bidirectional = 50mm
CLOSE

Device Record Status

8b8844f9-671b-446b-961b-35f8e54092d4
February 06, 2026
1
January 29, 2026
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE