DEVICE: Radmedix AcuityDR 1013 G4 (00810035220515)
Device Identifier (DI) Information
Radmedix AcuityDR 1013 G4
1
In Commercial Distribution
RADMEDIX, LLC
1
In Commercial Distribution
RADMEDIX, LLC
AcuityDR G4 combines components into a complete digital x-ray system upgrade kit, including software and digital radiography panels. The customer selects one of the following digital x-ray receptor panels: AcuityDR 1013 G4, AcuityDR 1417 G4, AcuityDR 1717 G4. The solid state imaging receptors can be used in wireless or tethered configuration. The indications for use remain unchanged: Intended for use by a qualified/trained physician or technician on both adult and pediatric subjects for taking diagnostic x-rays. Not for mammography. So the only difference between this submission and the predicate submission is the available selection of (previously cleared) digital panels. Each system consists of the following items: Customer supplies: Diagnostic x-ray generator (HF) Class I Code IZO. + Tubehead: Class I Code ITV
+ Tube Mount: Class I Code IYB + Attached Collimator, Manual (IZX) Class II 510(k) Exempt We supply: Digital X-Ray Receptor Panel 892.1680 Class II Code MQB. Digital X-ray Software 892.2050 Class II Code LLZ. The software offered for sale with this system has received previous 510(k) clearance in K210919.
We are supplying rebranded versions of the reference devices coupled with the AccuVue software cleared in our predicate K210919.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
61108 | Indirect flat panel x-ray detector |
An electrically-powered, cassette-like device intended to be used as part of an x-ray system to detect x-ray images following exposure, and create a digital signal; it is not dedicated to imaging of a specific anatomy. It includes two types of transducing technology (i.e., indirect): a scintillator [e.g. caesium iodide (CsI)] screen converts x-ray energy into light, followed by the conversion of light into a digital signal by photodiode array. The image data can be sent to an appropriate processing unit through a wired or wireless connection (e.g., Wi-Fi). It may be used in place of a fixed detector in x-ray imaging systems, e.g., as part of a digital imaging conversion system.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MQB | Solid State X-Ray Imager (Flat Panel/Digital Imager) |
LLZ | System, Image Processing, Radiological |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K231709 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
22e13888-740e-4756-9276-03ee20cdafcb
July 28, 2023
1
July 20, 2023
July 28, 2023
1
July 20, 2023
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found