DEVICE: primaLOK FF (00813210021983)
Device Identifier (DI) Information
primaLOK FF
800-1140-00
In Commercial Distribution
Wenzel Spine, Inc.
800-1140-00
In Commercial Distribution
Wenzel Spine, Inc.
primaLOK FF 40mm Implant Assembly, Sterile
The Wenzel Spine primaLOK FF Facet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of the facet joints. It is intended for use with or without bone graft, at a single or multiple levels from L1 to S1 inclusive. It is indicated for the posterior surgical treatment of any or all of the following: degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the facets with instability, trauma (i.e., fracture or dislocation), spondylolisthesis, spondylolysis, and pseudoarthrosis and failed fusions which are symptomatic or which may cause secondary instability or deformity. For transfacet fixation, the screws are inserted through the inferior articular process across the facet joint and into the pedicle. For translaminar facet fixation, the screws are inserted through the lateral aspect of the spinous process, through the lamina, through the inferior articular process, across the facet joint and into the pedicle.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46646 | Orthopaedic bone screw, non-bioabsorbable, sterile |
A small, sterile, threaded rod with a slotted head typically used for internal orthopaedic fracture fixation by being screwed into bone to hold plates or nails to bone or to provide direct interfragmentary stabilization of bone, or it may fasten soft tissue to bone; it is made of a material that cannot be chemically degraded or absorbed via natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre). There are a number of kinds available: cortical, cancellous, malleolar, scaphoid, partially-threaded and fully-threaded, self-tapping, and cannulated. A "lag screw" can be any of these used to obtain compression across bone fragments.
|
Obsolete | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MRW | System, Facet Screw Spinal Device |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K102438 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Room Temperature; Keep Dry |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 40 Millimeter |
Device Record Status
447481d4-8948-4f15-8b95-b4096adbb36e
February 19, 2024
3
June 26, 2018
February 19, 2024
3
June 26, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found