DEVICE: MotoBAND H10 Driver (00815432022687)
Device Identifier (DI) Information
MotoBAND H10 Driver
130515
Not in Commercial Distribution
130515
CROSSROADS EXTREMITY SYSTEMS
130515
Not in Commercial Distribution
130515
CROSSROADS EXTREMITY SYSTEMS
The MotoBAND™ CP Implant System is a bone plating system indicated for stabilization and fixation of fresh fractures, revision procedures, joint fusion and reconstruction of small bones of the hand, feet, wrist, ankles, fingers and toes. It consist of plates and screws.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
33968 | Surgical screwdriver, reusable |
A non-powered tool intended to fit into a screw head (e.g., slotted, cross/hex head) for the application of rotation to introduce/remove a screw (e.g., craniofacial bone screw, dental screw) into/from a patient in association with a surgical procedure [e.g., orthopaedic, dental, computer assisted surgery (CAS), image registration]. It may also be used to connect/disconnect a device to/from another device attached to a patient (e.g., implant component, fiducial marker). The proximal end of the device may have a handle for manual use or a profiled tang that fits into an independent chuck or power driver; it is typically made of metallic and/or polymer materials. This is a reusable device.
|
Active | false |
58776 | Surgical screwdriver, single-use |
A non-powered tool that fits into a screw head in order to apply rotation to tighten/loosen/remove a screw during a surgical procedure. It typically has a high-grade stainless steel shaft with a distal end dedicated to fit into a screw head that may be slotted, Phillips (cross head), Pozidriv (Supadriv), Torx, Hex (Allen), Robertson (square), spanner head (twin pins), Polydrive, or one-way (clutch). The proximal end of the shaft may have a handle for manual use, or it may have a profiled tang that fits into an interchangeable screwdriver handle, a manually-operated chuck, or a power driver. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HRS | Plate, Fixation, Bone |
HWC | Screw, Fixation, Bone |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
d72301db-4e67-4f8f-b759-6f38cd3d15e2
June 28, 2024
3
November 30, 2022
June 28, 2024
3
November 30, 2022
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]