DEVICE: MotoBAND (00815432023066)

Device Identifier (DI) Information

MotoBAND
MotoBAND CP Instrument Kit - Sterile
Not in Commercial Distribution
1500-4500
CROSSROADS EXTREMITY SYSTEMS
00815432023066
GS1
June 27, 2024
1
058864308 *Terms of Use
The MotoBAND™ CP Implant System is a bone plating system indicated for stabilization and fixation of fresh fractures, revision procedures, joint fusion and reconstruction of small bones of the hand, feet, wrist, ankles, fingers and toes. It consist of plates and screws. When used for these indications, certain plates within this system may be used with the MotoCLIP Implant System
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61807 Bone-resection orthopaedic reamer, single-use
An orthopaedic surgical instrument intended to resect bone (cut out part of the bone), and in some cases hypertrophic tissue [e.g., ligamentum flavum], to: 1) accept a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecranon of ulna); and/or 2) relieve pressure at or facilitate access to a joint. Commonly called a mill or a reamer, it is typically designed as a stainless steel cylindrical body with an end/circumferential cutting edge and is attached to a shaft for manual or powered rotation. This is a single-use device.
Active false
61806 Bone-resection orthopaedic reamer, reprocessed
An orthopaedic surgical instrument designed to resect bone (cut out part of the bone) and precisely shape a specific area of bone as it is advanced for the acceptance of a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecranon of ulna). Commonly called a mill or a reamer it is typically designed as either a preshaped or a solid cylindrical body with an end/circumferential cutting edge, and is attached to a shaft for manual or powered rotation. It is typically made of a high-grade stainless steel alloy available in varying sizes. This is a previously used single-use device that has been processed for an additional single-use patient application.
Active false
47746 Bone tack inserter, basic
A hand-held manual surgical instrument designed to drive (insert) a tack into bone, typically to fixate an orthopaedic plate or sheet. It is typically formed with a shaft made of high-grade stainless steel and a handle at the proximal end made of metal or synthetic material. The distal end is designed to hold (grip) the head of the tack head during insertion, typically through a hole in the plate or sheet and into a pre-drilled hole in the bone. This is a reusable device.
Active false
33997 Surgical drill guide obturator
A surgical device designed to fill the lumen of a drill guide during its insertion to a surgical site primarily to prevent tissue obstruction of the drill guide lumen. When the drill guide is firmly placed at the chosen position on the bone surface, the obturator is removed. It is typically a rod with a rounded distal end, which protrudes out of the drill guide, and a knob-like handle that functions as a regulator to control the length of the protruding end and to remove it from the drill guide. It is typically made of a high-grade stainless steel. This is a reusable device.
Active false
35095 Surgical drill guide, reusable
A manual surgical device designed to simultaneously place, angle, and guide a rotating surgical drill on hard tissue (e.g., bone); some types are also intended for guiding bone-coring instruments (e.g., keel punch). It is designed in a tubular form or with guiding holes and may have serrations at its distal end to enable firm placement on hard tissue surfaces (it is not bored into the tissue); it can have a handle or be held by another device (e.g., orthopaedic jig), and typically allows protection of the surrounding soft tissue during surgery. It is typically made of metal and may have graduations along its length; it is not custom-made for a specific patient. This is a reusable device.
Active false
57789 Surgical drill guide, single-use
A hand-held tubular surgical device designed to simultaneously place, angle, and guide a rotating surgical drill on hard tissue (e.g., bone), and to protect the surrounding soft tissue while the drill is in operation. It may have serrations at its distal end to enable firm placement on hard tissue surfaces (it is not bored into the tissue); it can have a handle at its proximal end for holding and manipulation, or it may be held by another device (e.g., orthopaedic jig). The device is typically dedicated to drill bit size, made of metal, and may have graduations along its length; it is not custom-made for a specific patient. This is a single-use device.
Active false
33968 Surgical screwdriver, reusable
A non-powered tool intended to fit into a screw head (e.g., slotted, cross/hex head) for the application of rotation to introduce/remove a screw (e.g., craniofacial bone screw, dental screw) into/from a patient in association with a surgical procedure [e.g., orthopaedic, dental, computer assisted surgery (CAS), image registration]. It may also be used to connect/disconnect a device to/from another device attached to a patient (e.g., implant component, fiducial marker). The proximal end of the device may have a handle for manual use or a profiled tang that fits into an independent chuck or power driver; it is typically made of metallic and/or polymer materials. This is a reusable device.
Active false
58776 Surgical screwdriver, single-use
A non-powered tool that fits into a screw head in order to apply rotation to tighten/loosen/remove a screw during a surgical procedure. It typically has a high-grade stainless steel shaft with a distal end dedicated to fit into a screw head that may be slotted, Phillips (cross head), Pozidriv (Supadriv), Torx, Hex (Allen), Robertson (square), spanner head (twin pins), Polydrive, or one-way (clutch). The proximal end of the shaft may have a handle for manual use, or it may have a profiled tang that fits into an interchangeable screwdriver handle, a manually-operated chuck, or a power driver. This is a single-use device.
Active false
47829 Surgical instrument handle, non-torque-limiting
A hand-held manual surgical instrument designed to attach to the proximal end of a surgical instrument (e.g., a screwdriver shaft) to allow the surgeon to perform manipulations with the instrument, such as manual rotation of a bone screw or reamer; it does not include a torque-limiting function. The device is typically made of metal and/or synthetic material and may have a straight or T-shaped handle grip which may include additional features such as a ratchet mechanism to allow the surgeon to maintain a constant hold on the handle when providing rotation in one direction. This is a reusable device.
Active false
58804 Surgical implant template, single-use
A device designed to determine the appropriate size and placement of a non-dental implant for a patient prior to or during implantation surgery. It is typically available as a graduated set or an individual plate (e.g., a translucent plastic sheet or a cut metal shape) with patterns/sizes corresponding to the size of the implant to be used to aid the surgeon in final selection of implant size, placement, and/or adaption. It is used for, e.g., total- or partial-joint prostheses, bone fracture fixation implants (plates, nails, including skull plate implants) or other types of surgical implants. This is a single-use device.
Active false
47749 Orthopaedic fixation plate bending insert, single-use
A non-sterile device that is inserted into the threaded or non-threaded hole of a metal orthopaedic fixation plate (e.g., trauma or craniofacial plate) prior to the surgeon bending the plate to conform to the anatomical shape of the implant site (e.g., jawbone or pelvis) in order to preserve the integrity of the holes which would otherwise deform, negating the entry of the bone screws that hold the plate in place. It is typically made of metal or synthetic material in the form of a short screw or pin-like device with a slotted head used solely during the bending of plates that typically have a continuous row of screw holes. This is a single-use device intended to be sterilized prior to use.
Active false
47748 Orthopaedic fixation plate bending insert, reusable
A device that is inserted into the threaded or non-threaded hole of a metal orthopaedic fixation plate (e.g., trauma or craniofacial plate) prior to the surgeon bending the plate to conform to the anatomical shape of the implant site (e.g., jawbone or pelvis) in order to preserve the integrity of the holes which would otherwise deform, negating the entry of the bone screws that hold the plate in place. It is typically made of metal or synthetic material in the form of a short screw or pin-like device with a slotted head (for the acceptance of a screwdriver) used solely during the bending of plates that typically have a continuous row of screw holes. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HWC Screw, Fixation, Bone
HRS Plate, Fixation, Bone
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K152306 000
K160300 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

15128de5-2951-4e0f-a6db-b6a6258eec12
June 28, 2024
16
May 10, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
901-221-8406
info@crextremity.com