DEVICE: STRoPP (00815432023783)
Device Identifier (DI) Information
STRoPP
STRoPP Plantar Plate Repair Kit - Sterile
In Commercial Distribution
1601-0002
CROSSROADS EXTREMITY SYSTEMS
STRoPP Plantar Plate Repair Kit - Sterile
In Commercial Distribution
1601-0002
CROSSROADS EXTREMITY SYSTEMS
The STROPP (Single Tunnel Repair of Plantar Plate) System is a sterile packaged kit that include PEEK implants and related instruments for plantar plate repair. Implants are packaged with the following manual surgical instruments for general use: a needle, needle passer, suture passer, an inserter, K-wires and distractor. The implants are compatible with Size 0 suture; suture is not included with the system. The STROPP System is intended for use with a suture in metatarsal ligament and tendon repairs.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
61143 | Suturing needle, single-use |
A cylindrical-shaped, solid, metal instrument intended to be used to insert and pull suture material through tissue (e.g., skin, fascia, serous, vascular, or other tissue/organ) during surgical stitching of tissues. It is available in various lengths, curvatures, diameters, cross-sectional shapes, and distal end forms. This is a single-use device.
|
Active | false |
57874 | Suturing unit, single-use |
A non-powered, hand-held device intended to pass sutures or a needle/suture assembly through tissues/prosthetic materials to facilitate suturing during an endoscopic and/or open surgical procedure; it may also knot, cut and/or tighten the sutures/ligature loop during or after placement. It typically consists of a shaft with hooks, catches, clasps, or forceps-like jaws at the distal end, and a proximal handle with controls. It typically has a pointed/cutting component to create a suture tunnel, and is loaded with the sutures or the suture is inserted through the shaft. This is a single-use device.
|
Active | false |
61807 | Bone-resection orthopaedic reamer, single-use |
An orthopaedic surgical instrument intended to resect bone (cut out part of the bone), and in some cases hypertrophic tissue [e.g., ligamentum flavum], to: 1) accept a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecranon of ulna); and/or 2) relieve pressure at or facilitate access to a joint. Commonly called a mill or a reamer, it is typically designed as a stainless steel cylindrical body with an end/circumferential cutting edge and is attached to a shaft for manual or powered rotation. This is a single-use device.
|
Active | false |
61806 | Bone-resection orthopaedic reamer, reprocessed |
An orthopaedic surgical instrument designed to resect bone (cut out part of the bone) and precisely shape a specific area of bone as it is advanced for the acceptance of a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecranon of ulna). Commonly called a mill or a reamer it is typically designed as either a preshaped or a solid cylindrical body with an end/circumferential cutting edge, and is attached to a shaft for manual or powered rotation. It is typically made of a high-grade stainless steel alloy available in varying sizes. This is a previously used single-use device that has been processed for an additional single-use patient application.
|
Active | false |
45062 | Tendon/ligament bone anchor, non-bioabsorbable |
A non-bioabsorbable device designed to be implanted into bone for the attachment of tendons/ligaments/soft tissues either directly or via a suture attached to the device; typically used in arthroscopic or open surgical procedures. This device is available in various designs and sizes and is made of a material that cannot be chemically degraded or absorbed via natural body processes [e.g., titanium (Ti)].
|
Active | true |
47568 | Suturing needle holder, single-use |
A hand-held manual surgical instrument designed to grasp a suture needle when pushing/pulling the needle and attached suture through tissue during suturing. It has short serrated jaws at the distal end to provide better grip of the needle, and is available in a wide variety of sizes and designs, such as: 1) a self-retaining, scissors-like design with ring handles at the proximal end; 2) a tweezers-like design with bowed, hinged handles that are operated by squeezing them together; and 3) a heavy-duty pincer-like design. This is a single-use device.
|
Active | false |
66935 | Orthopaedic intraoperative positioning pin, single-use |
A nonimplantable device in the form of a thin rod intended to be drilled into bone to assist with the positioning of an implantable device and/or surgical instrument (e.g., fixation plate, drill guide) during an orthopaedic procedure. It is also referred to as a wire or temporary K-wire. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MBI | Fastener, Fixation, Nondegradable, Soft Tissue |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Device Size Text, specify: 3.0mm Diameter x 8.0mm Length |
Device Record Status
8e7df9f4-f642-49fe-a5f9-2cb79173fb86
March 27, 2025
15
May 05, 2017
March 27, 2025
15
May 05, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
901-221-8406
info@crextremity.com
info@crextremity.com