DEVICE: MotoBAND™ CP DynaForce® MTP (00815432027958)
Device Identifier (DI) Information
MotoBAND™ CP DynaForce® MTP
DynaForce MTP Long Plate, 5deg valgus, 0deg dorsiflexion, 25mm Clip - Left
In Commercial Distribution
750L-0025
CROSSROADS EXTREMITY SYSTEMS
DynaForce MTP Long Plate, 5deg valgus, 0deg dorsiflexion, 25mm Clip - Left
In Commercial Distribution
750L-0025
CROSSROADS EXTREMITY SYSTEMS
The MotoBAND™ CP DynaForce® MPJ Implant System is a bone plating system indicated for stabilization and fixation of fresh fractures, revision procedures, joint fusion and reconstruction of small bones of the hand, feet, wrist, ankles, fingers and toes. It consist of plates and screws. Certain plates in the system are compatible with the MotoCLIP/DynaForce Superelastic Fixation System.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
61669 | Orthopaedic bone staple, non-adjustable |
A non-bioabsorbable, implantable device designed to be inserted into fractured bone to achieve fixation and repair; the device may also be used to attach/secure structures (e.g., ligaments/tendons) to bone, or to reduce/cease bone growth in skeletal deformities (e.g., by being implanted across epiphysial cartilage). It is typically a curved or U-shaped device made of metal alloy material, and is not adjustable after it has been applied. Guides for drilling integrated into the handle of the staple and disposable devices associated with implantation may be included.
|
Active | true |
46647 | Orthopaedic fixation plate, non-bioabsorbable |
A non-bioabsorbable, non-customized, firm, implantable sheet intended to stabilize a fractured orthopaedic bone (excluding craniofacial and spinal) to treat a traumatic/pathological fracture, to fuse a joint (arthrodesis) and/or as part of an osteotomy. Typically attached to a bone of a limb, rib, sternum, or pelvis, it is designed to be fixed in place with screws, and may be used in connection with another fixation plate; it does not incorporate a sleeve or blade. Instruments intended to facilitate implantation, or fixation implants (i.e., bone screws), may be included with the plate.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HRS | Plate, Fixation, Bone |
HWC | Screw, Fixation, Bone |
JDR | Staple, Fixation, Bone |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
1734ddea-8e1f-48e6-8dd9-5e36dc11377f
September 11, 2024
5
March 19, 2020
September 11, 2024
5
March 19, 2020
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
901-221-8406
info@crextremity.com
info@crextremity.com