DEVICE: PANTERA PLATE, RIGHT, 220mm (00816101011018)
Device Identifier (DI) Information
PANTERA PLATE, RIGHT, 220mm
NA
In Commercial Distribution
TO-PHP-R220
TOBY ORTHOPAEDICS
NA
In Commercial Distribution
TO-PHP-R220
TOBY ORTHOPAEDICS
The shoulder plates are made of titanium alloy and are designed in right and left configurations, as well as various length configurations. The plates are contoured to provide a close fit with the anatomy of the proximal humerus. The distal segment of the plate is provided with between 4 (73mm configuration) and 13 (220mm configuration) holes to accommodate 3.5mm diameter locking or non-locking cortical screws. The proximal segment of the plate has 2 locking screw holes and 3 locking post holes. Around the proximal end are also 4 suture clips.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46647 | Orthopaedic fixation plate, non-bioabsorbable |
A non-bioabsorbable, non-customized, firm, implantable sheet intended to stabilize a fractured orthopaedic bone (excluding craniofacial and spinal) to treat a traumatic/pathological fracture, to fuse a joint (arthrodesis) and/or as part of an osteotomy. Typically attached to a bone of a limb, rib, sternum, or pelvis, it is designed to be fixed in place with screws, and may be used in connection with another fixation plate; it does not incorporate a sleeve or blade. Instruments intended to facilitate implantation, or fixation implants (i.e., bone screws), may be included with the plate.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HRS | Plate, Fixation, Bone |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K081608 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
eb8e41bc-d711-466b-9463-c8ef1f1ee1bd
November 05, 2024
3
August 13, 2020
November 05, 2024
3
August 13, 2020
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
305-665-8699
sales@tobyortho.com
sales@tobyortho.com