DEVICE: HardyDisk™ (00816576021086)

Device Identifier (DI) Information

HardyDisk™
Z9245
In Commercial Distribution
Z9245
HARDY DIAGNOSTICS
00816576021086
GS1

250
039981550 *Terms of Use
Vancomycin 30μg (Va30) HardyDisk™ Antimicrobial Sensitivity Disks are used for semi-quantitative in vitro susceptibility testing by the agar diffusion test procedure (Kirby-Bauer) of rapidly growing and certain fastidious bacterial pathogens. Standardized methods for agar diffusion testing have been described for many organisms. Vancomycin is indicated for in vitro activity against gram positive, aerobic microorganisms including Staphylococcus spp., Enterococcus spp., and Streptococcus spp. The vancomycin disk diffusion test alone is unsuitable for detection of decreased susceptibility to vancomycin in Staphylococcus aureus. The CDC has recommended to incorporate the vancomycin screen agar plate (BHI with vancomycin) for susceptibility testing of all S. aureus isolates. Alternatively, the screening may be limited to methicillin resistant S. aureus (MRSA) isolates, since nearly all vancomycin intermediate S. aureus (VISA) are known to be resistant to methicillin and oxacillin.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
59213 Vancomycin susceptibility testing disc IVD
A susceptibility testing disc impregnated with a defined amount of the antimicrobial vancomycin, intended to be used to determine the antimicrobial susceptibility of a specific microorganism isolated from a clinical specimen by culture, using a disc diffusion method.
Obsolete false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
JTN Susceptibility Test Discs, Antimicrobial
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K000509 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between -20 and 8 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

2384d013-f45d-4686-85eb-4823cb120941
July 06, 2018
3
September 01, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 00816576021819 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
800-266-2222
techservice@hardydiagnostics.com
CLOSE