DEVICE: Histolock (00816765012840)
Device Identifier (DI) Information
Histolock
00711873
Not in Commercial Distribution
00711873
US Endoscopy
00711873
Not in Commercial Distribution
00711873
US Endoscopy
The Histolock resection kit (5-piece) contains the devices needed for injecting, resecting, and collecting flat lesions. The kit is made up of the Histolock Resection Device, Carr-Locke injection needle, eTrap polyp trap and Mio medical device organizer.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
58039 | Endoscopic electrosurgical handpiece/electrode, monopolar, single-use |
An electrosurgical device consisting of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver a current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece and requires a patient contact return electrode; it may include a suction/irrigation lumen and may feature a magnetic guidance sensor for electromagnetic tracking. It is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe) and may also be designed to mechanically cut tissues. This is a single-use device.
|
Active | false |
38825 | General-purpose endoscopic needle, single-use |
A flexible, sterile, sharp bevel-edged, hollow tubular device intended to be manually-operated through a compatible endoscope to perform various needle functions (e.g., injection, aspiration, irrigation, puncture) during endoscopy. It is designed with appropriate shape, materials, gauge, and other characteristics (e.g., high-contrast tips) to function through the working channel of an endoscope. This is a single-use device.
|
Active | false |
46454 | Gastrointestinal/airway foreign body retrieval basket, single-use |
A flexible device intended to access the gastrointestinal (GI) tract, and/or the airway tree, via the working channel of an appropriate endoscope to atraumatically remove foreign bodies during an endoscopic procedure; it may in addition be intended for removal of severed polyps and tissue samples (biopsy). It is typically designed with a long, thin, flexible body that has an expandable basket at the distal end in which objects are caught for extraction. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
FCG | Biopsy needle |
FDI | SNARE, FLEXIBLE |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 15 and 25 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
16ae9a47-ed94-4b21-9a6d-e0c771fdbf22
August 07, 2024
9
September 17, 2016
August 07, 2024
9
September 17, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
10816765012847 | 3 | 00816765012840 | 2020-03-31 | Not in Commercial Distribution | Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found