DEVICE: 14X17 Portable GOS Flat Panel Detector without USB (00817100020247)

Device Identifier (DI) Information

14X17 Portable GOS Flat Panel Detector without USB
PAN241
In Commercial Distribution

KONICA MINOLTA MEDICAL IMAGING U.S.A., INC.
00817100020247
GS1

1
080269345 *Terms of Use
IR 14X17 Portable GOS Flat Panel Detector without USB (-R or -L)
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61109 Diagnostic x-ray digital imaging conversion system
An assembly of medical devices designed to convert an existing analogue x-ray system to digital (i.e., retrofit) through the acquisition and processing of digital images using existing analogue x-ray system components. As a system it consists of both: 1) a filmless cassette-size digital detector (e.g., indirect flat panel detector); and 2) additional processing/viewing hardware [e.g., a central processing unit (CPU) with integrated software and a monitor]. Following acquisition the system is intended to also process, view, and/or store patient images as part of picture archiving and communication. It does not contain the controls for the direct operation of an x-ray imaging system.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between -20 and 60 Degrees Celsius
Handling Environment Humidity: between 5 and 90 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

eaf08771-e5c8-4e60-bb98-1cad39d118f4
February 21, 2019
3
September 24, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
No
No CLOSE

Customer Contact

[?]
1-800-366-5343
HTICSupport@konicaminolta.com