DEVICE: SOL-CARE™ Luer Lock Syringe with Safety Needle (00818392012064)
Device Identifier (DI) Information
SOL-CARE™ Luer Lock Syringe with Safety Needle
102215SN
In Commercial Distribution
Sol-Millennium Medical, Inc.
102215SN
In Commercial Distribution
Sol-Millennium Medical, Inc.
Used to inject medicines and vaccines into, or withdraw fluids from the body. In addition, the SOL-CARE™ Safety Needle is designed to aid in the prevention of needle stick injuries.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
47017 | General-purpose syringe, single-use |
A sterile device consisting of a calibrated barrel (cylinder) with plunger intended to be used for injection/withdrawal of fluids/gas (e.g., medication) to/from a medical device or the body (i.e., capable of both); a needle is not included. It is intended for various medical applications and is not dedicated to medication administration. At the distal end of the barrel is a male connector (typically Luer-lock/slip type) for the attachment to a hypodermic needle or an administration set. It is typically made of plastic and silicone materials and may have anti-stick plunger allowing smooth plunger movement, either manually or by a syringe pump. This is a single-use device.
|
Active | false |
59230 | Hypodermic needle, single-use |
A non-dedicated, sharp bevel-edged, hollow tubular device intended to be inserted beneath the skin of a patient while connected to a noninvasive device (e.g., syringe, secondary medication set) to administer and/or withdraw (aspirate) fluids/drugs; it may also be used for fluid/drug preparation. Some types are designed with a shielding mechanism (e.g., safety cap) for protection from sharp injuries. It is not specifically designed for blood collection or artery puncture, and does not have wings for fixation/placement (i.e., not a blood collection, intra-arterial, or venous butterfly needle). This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
FMI | Needle, hypodermic, single lumen |
FMF | Syringe, piston |
MEG | Syringe, Antistick |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 40 Millimeter |
Total Volume: 10 Milliliter |
Needle Gauge: 22 Gauge |
Device Record Status
ed433f44-7e2e-45a5-acd4-76399976b0d5
March 27, 2025
5
September 16, 2016
March 27, 2025
5
September 16, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
20818392012068 | 12 | 10818392012061 | In Commercial Distribution | Case | |
10818392012061 | 50 | 00818392012064 | In Commercial Distribution | Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
833-637-0857
info@solm.com
info@solm.com