DEVICE: Nonin (00833166001242)

Device Identifier (DI) Information

Nonin
3013 CH
In Commercial Distribution

NONIN MEDICAL, INC.
00833166001242
GS1

1
174959692 *Terms of Use
Xpod LP with 7000A, 6000CA for use with GE ApexPro CH
CLOSE

Device Characteristics

MR Unsafe
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
31658 Pulse oximeter probe, single-use
A photoelectric device designed to be applied externally to a body site (e.g., fingertip, ear lobe, bridge of nose, toe, or bridge of the foot) for the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in arterial blood using signals produced by a light-emitting diode (LED) and received by a photodetector. The signals are subsequently transmitted to an oximeter/monitor (not included) which measures and displays the SpO2. The is a single-use device.
Active false
17148 Pulse oximeter, line-powered
A mains electricity (AC-powered) photoelectric device intended for the continuous transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2). The signals, typically produced by light-emitting diodes (LEDs) and a receiving detector in a probe, or directly built-in, are used to make the measurements using the principle of spectrophotometry. The oximeter displays the SpO2 values and may calculate/display other parameters, e.g., pulse rate, electrocardiogram (ECG). The device is typically used bedside.
Obsolete false
45607 Pulse oximeter
An electrically-powered photoelectric device designed for the transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2). The signals are produced by light-emitting diodes (LEDs) and received by a photodetector. The device displays the SpO2 values and may also measure/display pulse rate. It is typically applied to the fingertip or around the wrist, may be single-component (with built-in probe) or multi-component (includes external probe), and may in addition wirelessly transmit measurements to a receiving location (e.g., central station, bedside monitor); it is intended to be operated by laypersons and healthcare providers.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DQA Oximeter
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K093853 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between -40 and 158 Degrees Fahrenheit
Storage Environment Temperature: between -40 and 70 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Adult
CLOSE

Device Record Status

3e895456-0ec9-4a98-8428-0cb1818e93e7
November 10, 2021
4
August 24, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
00833166001273 1 00833166001242 In Commercial Distribution Bag
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
763 553 9968
Regulatory@nonin.com
CLOSE