DEVICE: Discovery (00840682108218)
Device Identifier (DI) Information
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| No | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 40644 | PET system |
An assembly of devices comprising a diagnostic, positron emission tomography (PET) imaging system used to detect, record, quantify and analyse 511 kilo-electronvolt (keV) photon emission patterns resulting from annihilation reactions produced during the decay of positron emitting radiopharmaceuticals. It produces three-dimensional (3-D) tomographic digital cross-sectional physiological images representing distribution patterns of positron emitting radiopharmaceuticals ingested by, or injected into the patient. It typically uses lead collimators and specialized software for image reconstruction allowing mapping of metabolic patterns and rates associated with targeted physiological processes.
|
Active | false |
| 37618 | Full-body CT system |
An assembly of diagnostic x-ray computed tomography (CT) devices with a gantry large enough to allow imaging of any part of the body. It includes designs with single or multiple fixed annular arrays of x-ray tubes and opposing detectors or those with x-ray tube(s) and opposing detector assemblies that rotate rapidly around a central axis point within the gantry imaging area. It can produce two and/or three-dimensional (3-D) cross-sectional (tomographic) images, including spiral CT or other special imaging applications at multiple specified angles in relation to body position. It may use a variety of digital techniques for information capture, image reconstruction, and display.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| KPS | System, tomography, computed, emission |
| JAK | System, x-ray, tomography, computed |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K161574 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| No Device Sizes |
Device Record Status
ca5838dc-0789-404a-a51d-3fa28b7c0a99
July 06, 2018
3
October 11, 2016
July 06, 2018
3
October 11, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined