DEVICE: Alethia Malaria PLUS (00840733102257)

Device Identifier (DI) Information

Alethia Malaria PLUS
481125
Not in Commercial Distribution
481125
MERIDIAN BIOSCIENCE, INC.
00840733102257
GS1
October 21, 2022
1
092815364 *Terms of Use
The Alethia Malaria PLUS DNA amplification assays, performed on the Alethia Incubator/Reader, are qualitative in vitro diagnostic tests for the direct detection of Plasmodium sp. DNA in human venous EDTA whole blood specimens from individuals with signs and symptoms of malarial infection. Results from Alethia Malaria assays are intended to be used as an aid in the diagnosis of human malaria infection. Alethia Malaria assays utilize loop-mediated isothermal DNA amplification (LAMP) technology to detect Plasmodium sp. DNA by targeting segments of the Plasmodium genome. Alethia Malaria assays do not distinguish between Plasmodium species. Alethia Malaria PLUS is intended for use in hospital, reference or state laboratory settings. The device is not intended for nonlaboratory point-of-care use.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
52319 Multiple Plasmodium species nucleic acid IVD, kit, nucleic acid technique (NAT)
A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of nucleic acid from one or multiple species of Plasmodium (malaria parasites) in a clinical specimen, using a nucleic acid technique (NAT).
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
OAX Plasmodium Spp. Detection Reagents
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 2 and 30 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

e3fd9dd3-a209-4515-9c4f-8477ec08b2fc
August 22, 2023
2
October 26, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
513-271-3700
info@meridianbioscience.com