DEVICE: Mammotome (00841911100973)
Device Identifier (DI) Information
Mammotome
MHH11B
Not in Commercial Distribution
MHH11B
DEVICOR MEDICAL PRODUCTS, INC.
MHH11B
Not in Commercial Distribution
MHH11B
DEVICOR MEDICAL PRODUCTS, INC.
Hand-Held Probe
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 58990 | Side-notch biopsy gun handpiece/needle |
A hand-operated, non-electronic, surgical instrument designed for the automatic extraction of a small tissue sample from an anatomical structure (a biopsy), while causing minimal surrounding tissue damage, for tissue pathological examination/testing. It consists of both: 1) a handpiece with a spring-loaded mechanism and release trigger; and 2) a percutaneous, distal, needle-like portion with a side-notch cutter which when activated causes a sharp, sliding cannula to slice a segment of tissue. It is typically used to obtain samples of soft tissue from the kidneys, prostate, pancreas, liver, and breast, often performed under image guidance. This is a single-use device.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| KNW | Instrument, Biopsy |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K991980 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Needle Gauge: 11 Gauge |
Device Record Status
82525d45-d238-4e15-b6dc-272107d18f7a
August 11, 2025
6
October 24, 2016
August 11, 2025
6
October 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| 10841911100970 | 5 | 00841911100973 | 2022-05-13 | Not in Commercial Distribution |
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
877-926-2666
customersupport@mammotome.com
customersupport@mammotome.com