DEVICE: Radius-7 (00843997012997)
Device Identifier (DI) Information
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46201 | Pulse Co-oximeter |
A portable, battery-powered, electronic device designed to detect hypoxia (oxygen deficiency at the tissue level) via the transcutaneous multiwave measurement and display of carboxy-haemoglobin saturation (SpCO) and typically other related parameters such as haemoglobin oxygen saturation (SpO2), methaemoglobin saturation (SpMet), and haemoglobin concentration (SpHb); pulse rate and haematocrit may also be calculated. A light-emitting diode (LED) and a receiving detector in a probe applied to a body site (e.g., a fingertip) are used to make multiwave measurements using spectrophotometry. The device is used in healthcare settings or the home, often to evaluate carbon monoxide poisoning.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DQA | Oximeter |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Atmospheric Pressure: between 540 and 1060 KiloPascal |
Handling Environment Humidity: between 10 and 95 Percent (%) Relative Humidity |
Storage Environment Humidity: between 10 and 95 Percent (%) Relative Humidity |
Storage Environment Temperature: between -40 and 70 Degrees Celsius |
Handling Environment Temperature: between -40 and 70 Degrees Celsius |
Handling Environment Atmospheric Pressure: between 540 and 1060 KiloPascal |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
0c704317-c5da-4119-915b-667ee60c0435
October 01, 2019
1
September 23, 2019
October 01, 2019
1
September 23, 2019
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(949)297-7498
TechService-US@masimo.com
TechService-US@masimo.com