DEVICE: IFA EBV-EA IgG Test System (00845533001595)
Device Identifier (DI) Information
IFA EBV-EA IgG Test System
FA9152
In Commercial Distribution
FA9152
ZEUS SCIENTIFIC, INC.
FA9152
In Commercial Distribution
FA9152
ZEUS SCIENTIFIC, INC.
The ZEUS IFA Epstein-Barr Virus Early Antigen (EBV-EA) IgG Test System is a sensitive and relatively rapid indirect fluorescent antibody (IFA) method for the qualitative and quantitative detection of antibodies to early antigen (EA) of Epstein-Barr virus (EBV) in human sera. When performed according to instructions, the ZEUS IFA EBV-EA IgG Test System detects IgG antibodies to diffuse (D) and restricted (R) components of the EBV-EA complex. It is useful in providing information to support the diagnosis of infectious mononucleosis (IM). This device is for In Vitro diagnostic use only.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
49683 | Epstein-Barr virus (EBV) early antigen (EA) immunoglobulin G (IgG) antibody IVD, kit, fluorescent immunoassay |
A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of immunoglobulin G (IgG) antibodies to the early antigen (EA) of Epstein-Barr virus (EBV) in a clinical specimen, using a fluorescent immunoassay method. The assay is designed to detect infection with Epstein-Barr virus (EBV), the virus associated with infectious mononucleosis and glandular fever.
|
Obsolete | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
No Product Codes |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 2 and 8 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
6878d117-1f6b-44c8-b45d-f1cc34f609e1
March 29, 2018
2
September 24, 2016
March 29, 2018
2
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
No Customer Contact currently defined