DEVICE: AEQUALIS™ FLEX REVIVE™ (00846832074402)

Device Identifier (DI) Information

AEQUALIS™ FLEX REVIVE™
ARS980909
In Commercial Distribution
ARS980909
TORNIER, INC.
00846832074402
GS1

1
968990812 *Terms of Use
No description.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
39702 Coated shoulder humeral stem prosthesis
A sterile implantable device designed to provide fixation within the proximal humerus and a site of attachment for a humeral head or humeral body prosthesis as part of a shoulder joint replacement. The device is made of metal [e.g., titanium (Ti), cobalt-chrome (Co-Cr), stainless steel] and is coated with a material (e.g., porous materials, hydroxyapatite) intended to improve fixation and stability by promoting bone ingrowth. Fixation devices for implantation (e.g., screws) may be included and implantation may be performed with or without bone cement.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
PHX shoulder prosthesis, reverse configuration
HSD PROSTHESIS, SHOULDER, HEMI-, HUMERAL, METALLIC UNCEMENTED
KWS PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Outer Diameter: 13 Millimeter
Length: 130 Millimeter
CLOSE

Device Record Status

c299be83-8014-4890-8eb3-3ed90bb5646e
June 13, 2022
2
July 13, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
Yes
No
No CLOSE

Customer Contact

[?]
+1(888)494-7950
customerservice@tornier.com
CLOSE