DEVICE: InHealth Technologies (00848253003689)
Device Identifier (DI) Information
InHealth Technologies
VP 2210-LEF
In Commercial Distribution
Freudenberg Medical, LLC
VP 2210-LEF
In Commercial Distribution
Freudenberg Medical, LLC
No description.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
42533 | Tracheoesophageal speech valve, indwelling |
A device designed to be inserted into a surgically-created tracheo-oesophageal fistula after total laryngectomy to provide the patient with voice restoration. It is inserted and replaced on an as needed basis by a speech pathologist or clinician. It has a double flange (one on the outside of the throat and one on the inside) to hold it in place and includes a one-way valve that protects the airway during swallowing and opens under positive pressure so that air crosses into the oesophagus to produce voice (speech rehabilitation). The patient periodically cleans the device in situ. Disposable devices associated with implantation/insertion may be included. This is a single-use device.
|
Active | true |
62134 | Tracheoesophageal device insertion capsule |
A non-sterile, smooth, capsule-like device intended to house/cover a tracheoesophageal device (e.g., speech valve, fistula gauge) at the distal end of the introduction assembly, to enable atraumatic insertion of the device into the tracheoesophageal fistula (puncture). It is a synthetic polymer gelatinous casing intended to dissolve in situ for subsequent digestion; disposable devices intended to assist mounting may be included. It is intended to be used in the home and healthcare facility, and may be used in conjunction with a lubricant. This is a single-use device.
|
Active | false |
62127 | Tracheoesophageal device introducer |
A hand-held manual instrument designed to assist in the non-surgical placement of a tracheoesophageal device (e.g., speech valve, speech valve occluder, fistula gauge/dilator). It is a synthetic polymer holder onto which the tracheoesophageal device is distally mounted and directed to the target site through the tracheostoma. It is intended to be used by the patient at home (for non-indwelling devices) and clinician in the healthcare facility (for indwelling devices). This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
EWL | Prosthesis, Laryngeal (Taub) |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Keep away from sunlight; Keep dry |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
ee7fabc4-766d-4f61-b507-d7a941958f66
February 11, 2021
1
February 03, 2021
February 11, 2021
1
February 03, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
800-477-5969
inhealth@inhealth.com
inhealth@inhealth.com